Empire Comfort Systems CIBV-30-2 Indoor Fireplace User Manual


 
Page 4 R-3450
Figure 2
Figure 3
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed only
by a qualified agency. The term "qualified agency" means any individual,
firm, corporation,or company which whether in person or through a
representative is engaged in and is responsible for (a) the installation or
replacement of gas piping or (b) the connection, installation, repair or
servicing of equipment, who is experienced in such work, familiar with
all precautions required and has complied with all the requirements of the
authority having jurisdiction.
The installation must conform with local codes or, in the absence of local
codes, the current National Fuel Gas Code-ANSI Z223.1* (NFPA 54) or
CAN1-B149-Gas Appliance Installation Code.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence
de tels règlements, selon les Codes d'installation CAN/CGA-B149.
*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York,
N.Y. 10036.
Locating and Venting the Fireplace Heater (Figures 1, 2 and 3)
Clearances: When facing the front of the fireplace heater the minimum
clearances to combustible construction (material) are the following:
Open in front to provide service, access, and clearance to construction.
Top of appliance (ceiling) 36 (inches)
Draft Diverter to Rear Wall 2 (inches)
Side Wall 6 (inches)
Heater Corners (45° angle) to Wall 4 (inches)
Floor 0 (inches)
Figure 1