Empire Comfort Systems CIBV-30-2 Indoor Fireplace User Manual


 
Page 16 R-3450
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529
How To Order Repair Parts...
Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through
the distributor. Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list. Be sure to give all this information . . .
Heater Model Number Part Description
Heater Serial Number Kind of Gas (Propane or Natural)
Part Number
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
STANDING PILOT-TROUBLE SHOOTING
With proper installation and maintenance, your new Vented Fireplace Heater should provide years of trouble-free service. If you do experience
a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the
corrective action to be taken.
1. Spark ignitor will not light pilot after repeated depressing of
piezo ignitor button.
a. Defective ignitor (no spark at electrode)
- Check for spark at electrode and pilot; if no spark and electrode
wire is properly connected, replace ignitor.
b. No gas or low gas pressure.
- Check remote shut off valves from fireplace. Usually there is
a valve near the main. There can be more than one (1) valve
between the heater and main.
- Low pressure can be caused by a variety of situations such as
a bent line, too narrow diameter of pipe, or low line pressure.
Consult with plumber of gas supplier.
c. No LP in tank.
- Check LP (propane) tank. Refill tank.
2. Pilot will not stay lit after carefully following lighting instructions.
a. Defective thermopile.
- Check that pilot flame impinges on thermopile. Clean and/or
adjust pilot for maximum flame impingement.
- Ensure that the thermopile connection at the gas valve is tight.
3. Pilot burning, no gas to burner, valve knob "ON", on/off switch
"ON."
a. "On/Off" switch, wall switch, or wires defective.
- Check "on/off" switch and wires for proper connections. Place
jumper wires across terminal at switch - if burner comes on,
replace defective switch. If OK, place jumper wires across
switch wires at gas valve-if burner comes on, wires are faulty or
connections are bad.
b. Thermopile may not be generating sufficient milli-voltage.
- If the pilot flame is not close enough physically to the thermopile,
adjust the pilot flame.
- Be sure the wire connections from the thermopile at the gas
valve terminals are tight and the thermopile is fully inserted into
the pilot bracket.
- Check the thermopile with a millivolt meter. Take the reading
at TH-TP & TP terminals of the gas valve. The meter should read
325 millivolts minimum, while holding the valve knob depressed
the pilot position, with the pilot lit, and the ON/OFF switch in the
OFF position. Replace the faulty thermopile if the reading is
below the specified minimum.
- With the pilot in the ON position, disconnect the thermopile
leads from the valve. Take a reading at the thermopile leads. The
reading should be 325 millivolts minimum. Replace the
thermopile if the reading is below the minimum.
c. Defective valve.
- Turn valve knob to "ON." Place ON/OFF switch to "ON."
Check with millivolt meter at thermopile terminals. Millivolt
meter should read greater than 100 M.V. If the reading is okay
and the burner does not come, replace the gas valve.
d. Plugged main burner orifice.
- Check main burner orifice for blockage, clean main burner
orifice.
4. Frequent pilot outage problem.
a. Pilot flame may be too high or too low, or blowing (high),
causing pilot safety to drop out.
- Clean and adjust flame for maximum flame impingement on
the thermopile. Follow lighting instructions carefully.
5. The pilot and main burner extinguish while in operation.
a. No LP (Propane) in tank..
- Check LP (Propane) tank. Refill fuel tank.
b. Bad thermopile.
- Replace if necessary.
c. Improper vent cap installation.
- Check for proper installation and freedom from debris or
blockage.
6. Glass soots.
a. Flame impingement on logs.
- Adjust the log set so that the flame does not excessively
impinge on it.
b. Improper air shutter adjustment.
- Adjust the air shutter.
7. Flame lifts off main burner.
a. Insufficient oxygen being supplied.
- Check to make sure vent cap is installed properly and free of
debris. Make sure that vent system joints are tight and have no
leaks.
- Check to make sure that no material has been placed at the
burner base.
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.