Empire Comfort Systems CIBV-30-2 Indoor Fireplace User Manual


 
Page 20 R-3450
OPTIONAL BLOWER CIB-2
Vented Fireplace Heater CIBV-30
Installing Optional CIB-2 Blower
1. Loosen, but do not remove, (4) hex-head screws located on
the exterior, bottom of the appliance.
2. Position the blower assembly at the rear of the appliance. The
blower assembly has (4) keyholes for attachment to the
exterior, bottom of the appliance.
3. Place the large diameter holes in the keyholes over and behind
the (4) hex-head screws that were loosened in Step 1. Push
inward on the blower assembly to lock the keyholes into
position behind the screws. Tighten (4) hex-head screws to
secure blower assembly to exterior, bottom of the appliance.
4. Remove wire channel from rear cover by removing (4) hex-
head screws. Note: If optional blower is being installed
during initial installation of appliance, the wire channel will
not be attached to rear cover. (Refer to Installation of Wire
Channel Assembly, Page 8)
5. Attach fan control to FLAT, fan control bracket (Part 9A,
Page 21) with (2) 6 x 1/4" screws provided in hardware
package.
6. Attach fan control with bracket onto the wire channel by
using (2) 8 x 1/4" screws provided in hardware package.
7. Route wires from fan control and ON/OFF/REMOTE switch
within wire channel.
8. When facing the rear of the appliance, align and insert fan
control with bracket into 1 3/8" x 2" opening on the left side
of the rear cover.
9. Attach wire channel to rear cover by using (4) hex-head
screws removed in Step 4. (Refer to Installation of Wire
Channel Assembly, Page 8)
10. Insert AUTO/OFF/ON switch into rectangular notch on
valve bracket. Be sure to insert AUTO/OFF/ON switch
with letters (words) upright. (See wiring diagram)
11. Attach 1/4" push-on terminal from blue wire on the fan
control to the AUTO (top) tab on the switch.
12. Attach 1/4" push-on terminal from black wire to the OFF
(middle) tab on the switch.
13. Attach 1/4" push-on terminal from white wire on the fan
control to the ON (bottom) tab on the switch.
14. Installation of optional CIB-2 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type. The fan
control will require between 5 and 10 minutes of main burner
operation before the fan control "closes" and activates the
blower. The blower will continue to run between 5 and 10
minutes after the main burner shuts off, before the fan control
"opens" and deactivates the blower.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1, if an external electrical source is
utilized. This appliance is equipped with a three-prong
[grounding] plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug. For an ungrounded receptacle, an
adapter, which has two prongs and a wire for grounding, can
be purchased, plugged into the ungrounded receptacle and its
wire connected to the receptacle mounting screws. With this
wire completing the ground, the appliance cord plug can be
plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off: Turn temperature
dial or thermostat to lowest setting. Turn knob on gas
control to "OFF", depressing slightly. Do not force.