ULTRA FLAME DV “0” Clearance Fireplace
OPERATION
BEFORE LIGHTING
1) Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.
2) Make sure that there are no obstructions in the air intake or venting system.
3) Clear the immediate area of combustible materials, gasoline, and other flammable liquids and
vapours.
4) Make sure that the gas log is in its proper place.
THE FIRST FIRE:
During the first few hours of operation the appliance will release an odor. This is caused by the
burning off of residual oils used in the manufacturing process and by the curing of the high heat
paint. The ceramic glass window may require cleaning after this initial "burn in." Please read
the instructions on cleaning in the MAINENANCE section before doing so.
The optional gold plated items must be
absolutely clean before you light each fire. The acid
from your fingerprints may permanently etch the gold plating.
If the protective packaging that accompanied the gas log is still in place, follow the instructions
in the LOG PLACEMENT section.
LIGHTING PROCEDURE
WARNING: If you do not follow these lighting instructions exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
Open the pedestal cover front panel to reach the control.
Make sure the gas control knob is turned to the "off" position. If it is not, press knob slightly and
turn clockwise to the "off" position. Do not force the gas control knob. If the gas control was
in the on position you should wait 5 minutes before trying to re-light the fireplace.
• If you smell gas STOP and follow instructions on the COVER page.
• Push in and turn gas control knob counterclockwise to the "pilot" position.
6