Drolet DG05437/DG05447 Indoor Fireplace User Manual


 
ULTRA FLAME DV “0” Clearance Fireplace
VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION
Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the
building to prevent air passage. Install the vent terminal as shown. Insert the wall plate inside
the 8" pipe and screw it to the wall using the six #10 2-1/2" wood screws supplied. Place the 5"
locking band around the inner connector and insert the exhaust pipe. Seal the joint with RTV
silicone. Secure the pipe in place with one #10 1/2" metal screw. Install the casing and secure
with metal screws provided. Install the cover by inserting the tab in the slot on the wall plate
and secure with metal screws.
Seal around the terminal to prevent any water from leaking into the house. Seal both ends of the
slot where the cover was inserted in wall plate with RTV silicone.
VENT TERMINAL, BASEMENT INSTALLATION
Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the
building to prevent air infiltration.
Attach the 4" flexible pipe with the locking band and with RTV silicone.
Attach the wall plate with 4 wood screws # 10 x 2-1/2" (supplied).
Seal around the terminal to prevent water leakage into the house.