ULTRA FLAME DV “0” Clearance Fireplace
INSTALLATION
SAFETY NOTICE
Improper installation may result in a house fire. Follow installation directions. Installation must
be in accordance with local building codes or, in the absence of local codes, with current
CAN/CGA B 149 installation codes for gas appliances in Canada and current National Fuel Gas
Code ANSI Z223.1 in the USA.
INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.
THIS GAS FIREPLACE MUST BE VENTED OUTSIDE.
THIS GAS FIREPLACE, WHEN INSTALLED WITH OPTIONAL BLOWER OR HAND
HELD REMOTE, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH
LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE National Electrical
Code, ANSI/FPA 70, or the CANADIAN ELECTRICAL CODE, CSA C22.1.
POSITIONING THE FIREPLACE
• WARNING: Because of high operating temperatures, the ULTRA FLAME should be
located away from high traffic areas, furniture, curtains, and other combustible material.
• Always locate the fireplace as near as possible to an outside wall to keep vent length to a
minimum.
• Provide adequate accessibility clearances for servicing and proper operation.
• Provide adequate clearances around air openings into the combustion chamber.
• The ULTRA FLAME may be installed in a bedroom provided that all required clearances are
met and a wall thermostat is installed.
• Never install the fireplace in a hallway or near a staircase as it may block the way in case of a
fire.
• If the appliance is being installed on combustible flooring, such as directly on carpeting, tile,
or other combustible material other than wood flooring, the appliance shall be installed on a
metal or wood panel extending the full width and depth of the appliance.
A GAS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING
A SEPARATE SOLID-FUEL BURNING APPLIANCE.
11