Drolet DG05437/DG05447 Indoor Fireplace User Manual


 
ULTRA FLAME DV “0” Clearance Fireplace
GLASS FRONT REMOVAL, CLEANING AND INSTALLATION
Removal :
Let the fireplace cool down for at least one hour.
Open top and bottom louvres exposing the front retaining clamps
Open the four clamps (bottom 2 first)
Remove the glass front assembly.
CAUTION : Do not operate your fireplace without a glass front or with a broken glass.
Cleaning :
Only clean the glass when cold.
Clean with liquid type cleaners or soap and water; do not use abrasive cleaners,
which can scratch the glass.
Installation :
Put the glass front assembly back in position.
Insert the hooks of all four clamps into the glass front.
Tighten both top clamps simultaneously.
Tighten both bottom clamps simultaneously.
Close the louvres.
BURNER REMOVAL AND INSTALLATION
REMOVAL :
Remove the glass front assembly.
Lift out the grate and hearth insert around burner.
Unscrew the retaining screws on each side of the burner.
Slide burner to the left and lift out.
22