ULTRA FLAME DV “0” Clearance Fireplace
SPECIFICATIONS
Dimensions: height 39", width 36", depth 20"
Glass: 29-1/8" x 17-3/4" 1400
o
F clear ceramic
Minimum opening in wall for installing the units:
height: 39-1/2"
width: 36-1/2"
Fuel: Natural Gas Propane
Input : 30,000/ 20,000 26,000/20,000 Btu/h
Manifold pressure : 3.5/1.8 10.5/7.0 in w.c.
Min. inlet pressure : 5 11 in w.c.
Max. inlet pressure : 7 14 in w.c.
Efficiency: 75%
Vent size: 4" inner 8" outer coaxial vent pipes
Valve: SIT Model Nova 820 adjustable millivolt valve
Blower: Variable speed, 200 CFM
Thermo-switch: 120
o
F "ON", 90
o
F "OFF" bi-metal type
Pressure relief device: Burst disc
Maximum length of venting pipe allowed:
Straight out installation: - Vertical rise: 0’
- Max horizontal length: 5'
- Max combination of both: 5’
Corner installation: - Vertical rise: 0’
- Max horizontal length: 5'
- Max combination of both: 5’
Basement installation: - Max vertical rise: 25'
- Max horizontal length: 10'
- Max combination of both: 25'
Maximum number of elbows 90° or 45°: 3
5