CLEARANCES
Minimum clearances to combustibles for the
replace are as follows:
*Back and sides 0"
Perpendicular walls 6"
Floor 0"
Ceiling to louver opening 42"
Front 36"
Top of Standoffs 0"
Vent (See venting instructions
for specic venting
clearances.)
Combustible material with a maximum thick-
ness of 5/8" may be ush with the top front
of replace.
* For back and sides of replace, do not pack
with insulation or other materials. 0" clear-
ance to combustible materials are for framing
purpose only.
NOTICE: This replace is intend-
ed for use as supplemental heat.
Use this replace along with
your primary heating system.
Do not install this replace as
your primary heat source. If you
have a central heating system,
you may run system’s circulat-
ing blower while using replace.
This will help circulate the heat
throughout the house.
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation.
All minimum clearances must be met.
If you are using a separate combustible man-
tel piece, refer to Figure 6 for proper instal-
lation height. You can install noncombustible
mantels at any height above the replace.
Note: Noncombustible mantels may discolor!
PREINSTALLATION
Continued
56
3
/
4
"
43
1
/
4
"
33" 28"
Figure 4 - Framing Clearances with
Outside Air Flex Duct
41
3
/
8
"
82
1
/
8
"
43
1
/
4
"
43"
19
9
/
16
"
58
1
/
4
"
Nailing
Tabs
Figure 5 - Framing Clearances for
Corner Installation
Figure 6 - Clearances for Combustible
Mantels
C
B
A
D
E
F
G
3
2
1
4
5
6
7
Wall
Ref.
Mantel
Depth Ref.
Mantel
from Top of
Opening
1 14" A 16"
2 12" B 14"
3 10" C 12"
4 8" D 10"
5 6" E 8"
6 4" F 6"
7 2" G 4"