Design Dynamics DVF-36S-N Indoor Fireplace User Manual


 
www.desatech.com
120441-01A 11
2' Min.
2' Pipe Min.
+ 90° Elbow
7' Min.
VENTING INSTALLATION
Continued
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Siding
Standoff
Screws
High Wind
Termination
Apply
Mastic to
Outside
Edge of
Standoff
Exterior Wall with Vinyl Siding
11
1
/
2
" x 11
1
/
2
"
Framed Opening
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
Minimum
Pipe
Overlap
1
1
/
4
"
Wall
Firestop
Direct
Vent
Pipe
Horizontal Termination Congurations
Figures 14 and 15 show different con-
gurations and alternatives for venting with
horizontal termination. Each gure includes
a chart with critical minimum and maximum
dimensions which MUST be met.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a re. Operation of
improperly installed and main-
tained venting system could
result in serious injury, property
damage or loss of life.
GROUND FLOOR INSTALLATION
Recommended Applications:
Installation using cabinet surrounds
Through the wall using round or square
termination (up to 12" horizontal pipe)
NOT FOR CORNER INSTALLATION
Horizontal High
Wind Square
Termination
Wall
Firestop
90° Elbow
Figure 14 - Horizontal Termination Using
One 90° Elbow
Venting with Two 90° Elbows
Vertical (V)
Horizontal (H
1
) +
Horizontal (H
2
)
7' min. 18' max.
8' min. 20' max.
20' max. 20' max.
Figure 15 - Horizontal Termination Using
Two 90° Elbows