Desa VMH26NR8 Indoor Fireplace User Manual


 
www.desatech.com
113110-01H32

Slight smoke or odor during
initial operation
Fireplace produces a whistling
noise when burner is lit
White powder residue forming
within burner box or on adja-
cent walls or furniture
Moisture/condensation noticed
on windows
REMEDY
1. Problem will stop after a few
hours of operation
2. Check burner for dirt and
debris. If found, clean
burner (see Cleaning and
Maintenance, page 28)
3. Replace gas regulator
1. Turn control knob to LO
position and let warm up
for a minute
2. Operate burner until air is
removed from line. Have
gas line checked by local
natural gas company
3. Observe minimum instal-
lation clearances (see
page 10)
4. Clean burner (see Cleaning
and Maintenance, page 28)
or replace burner orice
1. Turn fireplace off when
using furniture polish, wax,
carpet cleaners, or similar
products
1. Refer to Air for Combustion
and Ventilation require-
ments (page 6)

1. Residues from manufac-
turing processes and log
curing
2. Not enough air
3. Gas regulator defective
1. Turning control knob to
HI position when burner
is cold
2. Air in gas line
3. Air passageways on re-
place blocked
4. Dirty or partially clogged
burner orice
1. When heated, vapors
from furniture polish, wax,
carpet cleaners, etc. may
turn into white powder
residue
1. Not enough combustion/
ventilation air
TROUBLESHOOTING
Continued