Note: During initial operation, slight smoking
could occur due to log curing and replace
burning manufacturing residues.
8. To prevent the creation of soot, follow
the instructions in Cleaning and Mainte-
nance, page 28.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn replace
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
10. This replace needs fresh air ventilation to
run properly. This replace has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the re-
place if not enough fresh air is available.
See Air for Combustion and Ventilation,
page 6. If replace keeps shutting off, see
Troubleshooting, page 30.
11. Do not run replace
• where ammable liquids or vapors are
used or stored.
• under dusty conditions.
SAFETy
Continued
Figure 1 - Vent-Free Compact Classic
Hearth
®
Fireplace
Screen
Fireplace
Cabinet
Logs
Ignitor
Button
Remote Control
(Optional)
Selector
Switch
(Optional)
Control
Knob
OPTIONAL REMOTE
CONTROL ACCESSORIES
There are four optional remote controls that
can be purchased separately:
• wall switch
• hand-held ON/OFF remote
• wall thermostat
• hand-held thermostat remote
See Accessories, page 35.
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
12. Do not use this replace to cook food or
burn paper or other objects.
13. Never place any objects in the replace
or on logs.
14. Do not use replace if any part has been
under water. Immediately call a qualied
service technician to inspect the room
replace and to replace any part of the
control system and any gas control which
has been under water.
15. Turn off and unplug fireplace and let
cool before servicing. Only a qualied
service person should service and repair
replace.
16. Operating replace above elevations of
4,500 feet could cause pilot outage.
17. Do not operate fireplace if any log is
broken. Do not operate replace if a log
is chipped (dime-sized or larger).
18. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lbs. capacity.
19. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION