WIRING DIAGRAMS
SPECIFICATIONS
WIRING DIAGRAMS
Power Plug
120V/60Hz
Blue
Blue
White
White
Photocell
Green
Green
Red
Black
Yellow
Yellow
Motor
Ignitor
Ignition Control Assembly
Photocell
Photocell
Ignitor
Motor Return
AC Neutral (L2)
120V (L1)
Ignitor
Motor
Figure 34 - Wiring Diagram without Thermostat (40/55/60/70/110/115/155/165 Models)
Model Size 40 55/60 70 110/115 155 165 200
Output Rating (Btu/Hr) 40,000 55,000 70,000 110,000 155,000 165,000 200,000
and 60,000 and 115,000
Fuel Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*
Fuel Tank Capacity
(U.S. Gal./Liters) 3/11.3 5/18.9 5/18.9 9/34 13.5/51 13.5/51 13.5/51
Fuel Consumption
(Gal. Per Hr/Liters Per Hr) .3/1.14 .44/1.67 .52/1.97 .85/3.00 1.14/4.31 1.2/4.54 1.4/5.3
Pump Pressure (psi) 3.0 3.4 4.7 5.1 5.2 5.6 6.2
Electric Requirements 120 V/60 HZ (Same All Models)
Amperage (Normal Run) 2.0 2.0 2.8 3.6 3.6 3.6 3.6
Motor RPM 1725 1725 3440 3400 3400 3400 3400
Hot Air Output (CFM) 170 180 360 490 550 575 600
Motor HP 1/15 1/15 1/8 1/5 1/5 1/5 1/4
Shipping Weight 32/14.5 33/15 35/15.9 54/24.5 63/28.6 65/29.5 77/35
(Approximate Pounds/Kilograms)
Heater Weight without Fuel 28/12.7 29/13.1 31/14 46/21 54/24.5 55/25 66/30
(Approximate Pounds/Kilograms)
* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in extreme cold