119315-01A 29
SPECIFICATIONS
SERVICE HINTS
• pilot will not stay lit
• burners will have delayed ignition
• replace will not produce specied heat
• for propane/LP units, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If so, con-
tact your local natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department at
1-866-672-6040. When calling, please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ techni-
cal services web site at .
REPLACEMENT PARTS
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating Products’ Technical Service
Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your replace
• how replace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products at 1-866-672-6040 for
referral information.
When calling DESA Heating Products, have ready
• model number of your replace
• the replacement part number
WIRING DIAGRAM
Red
Jumper Wire
White
Thermopile
Gas Control
TPTH TH
TPTH
TP
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Electronic Ignitor
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
* For purpose of input adjustment
CGMFN
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
• Ignition: Electronic Ignitor
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
* For purpose of input adjustment
ALL MODELS
• Dimensions (HxWxD): Fireplace (including hood and screws) - 23
3
/
4
" x 19
3
/
4
" x 8
7
/
8
"
• Weight: Fireplace - 30 lbs., Shipping: 33 lbs.