Safety Features
When away from home for an extended period of
time or as a child safety feature to prevent accidental
ignition of the replace, receiver ON/OFF/REMOTE
switch should be in the OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds 82°
Fahrenheit (28° Centigrade), the hand-held
remote control will perform a safety override
and shut the replace off. This feature is not
available in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the replace after 8 minutes.

This feature allows the user to lock/unlock
the keypad on the hand-held remote in the
MANU or AUTO mode to prevent inadvertent
operation (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.


Make sure the heater switch is on REMOTE
and set the temperature adjustment on wall
thermostat to the desired setting. The thermo-
stat has been electronically calibrated at the fac-
tory and requires no adjustment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
See installation instructions on page 17 of this
manual.
GWMS2 WALL MOUNTED

Make sure the heater switch is on REMOTE.
This wall switch works just like the conven-
tional light switch. Flip the switch up for on
and down for off.
Note: Make sure that this switch is not in a
position to be mistaken for a light switch. This
may result in the replace being inadvertently
turned on without the proper precautions being
taken. See installation instructions on page 18
of this manual.
OPERATING FIREPLACE
Continued
INSPECTING BURNERS
Check pilot ame pattern and burner ame pat-
terns often.

Figure 36 shows a correct pilot ame pattern. Figure
37 shows an incorrect pilot ame pattern. The incor-
rect pilot ame is not touching the thermocouple.
This will cause the thermocouple to cool. When the
thermocouple cools, the replace will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 37
turn replace off (see To Turn Off Gas to Appli-
ance, page 20 for Manual-Controlled Models
or page 21 for Remote-Ready Models)
see Troubleshooting, page 31
Note: The correct pilot ame on natural gas units
will have a slight curve, but ame should be blue
and have no yellow or orange color.
Figure 36 - Correct Pilot Flame Pattern
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple
Figure 37 - Incorrect Pilot Flame Pattern
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple

Figure 38, page 24, shows a correct burner ame
pattern. Figure 39, page 24, shows an incorrect
burner ame pattern. The incorrect burner ame
pattern shows sporadic, irregular ame tipping.
The ame should not be dark or have an orange/
reddish tinge.
Note: When using the replace the rst time, the
ame will be orange for approximately one hour