Desa CGMFN Indoor Fireplace User Manual


 
www.desatech.com
119315-01A 13
INSTALLATION
Continued

-

    


 -
-


WARNING: Never connect

   
    

IMPORTANT: For natural gas, check gas line
pressure before connecting replace to gas line.
Gas line pressure must be no greater than 14" of
water. If gas line pressure is higher, heater regula-
tor damage could occur.
-


   



For propane/LP units, the installer must supply
an external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas pressure,
replace regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 13. Pointing the vent down
protects it from freezing rain or sleet.
Propane/LP
Supply Tank
External Regulator
Figure 13 - External Regulator With Vent
Pointing Down
Vent Pointing Down
CAUTION: Use only new,
     -


     




Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up. NPT
tap must be upstream from heater (see Figure 14,
page 14).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.
Check your building codes for any special re-
quirements for locating equipment shutoff valve
to replaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged replace valves.
    

