Cloudmark 3048 Home Security System User Manual


 
Cloudmark Cartridge Installation and Administration Guide Appendix A
42 WARN log messages
high accuracy, it is important to wait until files are successfully downloaded from
the network before passing messages through the cartridge.
Can not read information about micro-update directory <cachedir>
(<disk_error>). This warning is logged when the cartridge is unable to read
any information about the configured micro-updates directory. This message will
not be logged if the directory does not exist. In that case, it will attempt to create
the directory instead.
Micro-update directory <cachedir> must be a writable directory.
This warning is logged when the configured micro-update cache directory exists,
but is not a writable directory.
Could not load <mu_source> files from disk
(<disk_error|decode_error>). This message is logged when the cartridge
attempts to read cached micro-update files from disk but fails. This message will
be logged only if the cartridge is configured to perform micro-update downloads,
as it can fall back to network-based downloads. If the cartridge is not configured
to perform micro-update downloads, it will log an error message instead of a
warning message.
Could not load <mu_source> files from disk
(<disk_error|decode_error>). This message is logged when the cartridge
attempts to read cached micro-update files from disk but fails. This message will
be logged only if the cartridge is configured to perform micro-update downloads,
as it can fall back to network-based downloads. If the cartridge is not configured
to perform micro-update downloads, it will log one of the below errors instead.
Can not remove old <mu_source> files (<disk_error>). This message
is logged when the cartridge attempts to remove an old file (i.e. the one with the
lowest serial number) below the micro_updates directory but fails. The cartridge
will keep at most 2 micro-updates files for a source at any one time.
Can not resolve [micro-update, http proxy] hostname <host>
(<net_error>), expect micro-update downloads to fail. This message is
logged at startup when the cartridge cannot resolve the configured micro-update
host to an IP address. This typically indicates a problem with DNS resolution at
the installation. Cartridge accuracy will be significantly reduced without current
micro-update files, so the problem should be identified and solved as quickly as
possible.
Could not remove signature <sig> from local set This message is
logged when a downloaded micro-update file contains a signature that is already
present in the in-memory set of signatures. This warning can occur in rare