Clarion MS8300 Home Security System User Manual


 
After 5 seconds, the Transmitters LED will begin to flash rapidly, indicating the
signal to turn off the Logic Sensor II is being transmitted.
The siren will emit three chirps confirming the signal has been received and will
ignore the Logic Sensor II until next time the system is armed.
4. Audible Tamper Alert Report. When Audible Tamper Alert is selected, the siren will chirp
to indicate which zone had triggered the system, upon disarming.
If the system was triggered, the siren will emit one long chirp, followed by a series of short
chirps indicating the violated zone.
1 chirp = door
2 chirps = Logic Sensor II (shock)
3 chirps = Space Shield III or Optional sensor
4 chirps = hood/trunk
5 chirps = Logic Sensor II (motion)
When Audible Tamper Alert report is turned off, the siren will emit a long chirp on disarming
to indicate the system was triggered, but the zone indication will be from the status LED
only.
5. Door Unlock Pulse - Single/Double. Selects between a
single
pulse or a
double
pulse
door unlock output.
On many late model Nissan vehicles, as well as some European makes, the factory door
locking system requires two pulses on the proper wire to unlock the vehicles doors. By
programming the system for double pulse door unlocking, these systems can be interfaced
directly without the use of relays or any additional circuitry.
6. Siren Duration - Instant Triggers. Selects between a 20 second and a 40 second siren
duration when the system is triggered by the instant trigger inputs (doors, hood/trunk,
ignition).
7. Siren Duration - Sensors. Selects between a 20 second and a 40 second siren duration
when the system is triggered by the sensors (Logic Sensor II or optional sensors).
8. Radar Sensor - Warn Away Trigger. When selected, this feature will set the system to
trigger if it senses 3 violations on the Radar Sensor Warn Away input (Violet/yellow) within
15 seconds.
When this feature is turned off, the Warn Away input will only cause the siren to chirp and
will not trigger the system.
9. Full Time System Diagnostics Delay - 0 or 20 seconds. Ungos Full Time System
Diagnostics continuously monitors the protected zones, even when the system is disarmed,
and warns the user of an open door, hood, or trunk switch by emitting two chirps.
When set for 20 seconds, the delay will only allow the system to emit the warning chirps if
a protected zone has been open or defective for at least 20 seconds.
This feature is useful for people who are in the habit of opening the vehicles door before
turning off the ignition key and do not want the warning chirps unless a zone has been open
for a least 20 seconds.
MS8200 / MS8300 Installation Manual - Page 19
installation_rev3.qxd 7/26/99 6:07 PM Page 19