Bryant GT-PG (50YE) Heating System User Manual


 
GT-PG
8
GT-PG (50YE) Series
Bryant: Whatever it Takes.
AHRI/ISO/ASHRAE/ANSI 13256-1 Performance
ASHRAE/AHRI/ISO 13256-1. English (I-P) Units
ASHRAE/AHRI/ISO 13256-1. Metric (S-I) Units
Model
Fan
Motor
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 30°C Heating 20°C Cooling 15°C Heating 10°C Cooling 25°C Heating 0°C
Capacity
Watts
EER
W/W
Capacity
Watts
COP
Capacity
Watts
EER
Watts
Capacity
Watts
COP
Capacity
Watts
EER
W/W
Capacity
Watts
COP
TS018
PSC 5,470 4.4 6,764 5.2 6,264 7.3 5,529 4.5 5,735 5.4 4264 3.6
ECM 5,647 4.8 6,852 5.9 6,500 7.7 5,558 4.9 5,941 5.7 4,426 3.9
TS024
PSC 7,356 4.7 8,675 4.9 8,382 7.5 7,327 4.3 7,708 5.6 5,569 3.7
ECM 7,327 5.0 8,792 5.3 8,236 8.0 7,356 4.6 7,620 5.9 5,686 3.8
TS030
PSC 8,265 4.5 10,229 5.0 9,291 6.7 8,617 4.4 8,617 5.2 6,917 3.8
ECM 8,382 4.6 10,317 5.3 9,437 7.0 8,617 4.6 8,734 5.3 6,946 3.9
TS036
PSC 9,672 4.9 11,665 5.5 10,932 7.4 9,642 4.8 10,111 5.6 7,532 3.9
ECM 9,701 5.2 11,577 5.8 10,932 7.8 9,642 5.1 10,141 5.9 7,562 4.2
TS042
PSC 10,961 4.7 14,478 5.4 12,573 7.1 11,753 4.6 11,518 5.4 9,261 3.8
ECM 11,079 5.0 14,244 5.7 12,954 7.9 11,518 4.9 11,723 5.9 8,910 4.0
TS048
PSC 13,775 4.5 17,585 5.0 15,797 6.8 14,361 4.4 14,625 5.2 11,430 3.7
ECM 13,951 4.7 17,497 5.2 15,856 7.2 14,273 4.5 14,683 5.4 11,254 3.8
TS060
PSC 17,878 4.7 20,633 5.0 19,637 6.8 17,204 4.5 18,552 5.3 13,628 3.7
ECM 17,878 4.8 20,750 5.2 19,695 7.1 17,321 4.6 18,757 5.6 13,687 3.8
ECM 19,637 4.5 24,883 5.0 22,567 6.9 20,223 4.4 20,516 5.2 15,797 3.6
Cooling capacities based upon 27°C DB, 19°C WB entering air temperature
Heating capacities based upon 20°C DB, 15°C WB entering air temperature
All ratings based upon operation at lower voltage of dual voltage rated models
018
024
030
036
042
048
070
060
Model
Fan
Motor
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling 86°F Heating 68°F Cooling 59°F Heating 50°F Cooling 77°F Heating 32°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
TS018
PSC 18,600 15.0 23,000 5.2 21,300 24.8 18,800 4.5 19,500 18.4 14,500 3.6
ECM 19,200 16.5 23,300 5.9 22,100 26.3 18,900 4.9 20,200 19.4 14,500 3.9
TS024
PSC 25,100 16.2 29,600 4.9 28,600 25.7 25,000 4.3 26,300 19.1 19,000 3.7
ECM 25,000 17.0 30,000 5.3 28,100 27.4 25,100 4.6 26,000 20.0 19,400 3.8
TS030
PSC 28,200 15.3 34,900 5.0 31,700 22.9 29,400 4.4 29,400 17.6 23,600 3.8
ECM 28,600 15.6 35,200 5.3 32,200 23.9 29,400 4.6 29,800 18.0 23,700 3.9
TS036
PSC 33,000 16.6 39,800 5.5 37,300 25.1 32,900 4.8 34,500 19.2 25,700 3.9
ECM 33,100 17.6 39,500 5.8 37,300 26.5 32,900 5.1 34,600 20.2 25,800 4.2
TS042
PSC 37,400 16.0 49,400 5.4 42,900 24.3 40,100 4.6 39,300 18.4 31,600 3.8
ECM 37,800 17.1 48,600 5.7 44,200 27.1 39,300 4.9 40,000 20.0 30,400 4.0
TS048
PSC 47,000 15.3 60,000 5.0 53,900 23.3 49,000 4.4 49,900 17.6 39,000 3.7
ECM 47,600 15.9 59,700 5.2 54,100 24.6 48,700 4.5 50,100 18.5 38,400 3.8
TS060
PSC 61,000 15.9 70,400 5.0 67,000 23.2 58,700 4.5 63,300 18.2 46,500 3.7
ECM 61,000 16.4 70,800 5.2 67,200 24.3 59,100 4.6 64,000 19.0 46,700 3.8
TS070
ECM 67,000 15.2 84,900 5.0 77,000 23.5 69,000 4.4 70,000 17.8 53,900 3.6
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon operation at lower voltage of dual voltage rated models
018
024
030
036
042
048
060
070