Bryant GT-PG (50YE) Heating System User Manual


 
GT-PG
14
GT-PG (50YE) Series
Bryant: Whatever it Takes.
Performance Data — GT-PG Model 018 - ECM Blower
Operation not recommended
Operation not recommended
750 CFM Nominal (Rated) Air ow Cooling, 750 CFM Nominal (Rated) Air ow Heating Performance capacities shown in thousands of Btuh
EWT
°F
GPM
WPD Cooling - EAT 80/67°F Heating - EAT 70°F
PSI FT
Air ow
CFM
TC SC kW HR EER HW
Air ow
CFM
HC kW HE LAT COP HW
20
5.5 3.9 9.0
550 0.0 0.0 0.00 0.0 0.0 0.0 550 11.9 1.25 7.9 90.0 2.8 1.4
5.5 3.9 9.0
750 0.0 0.0 0.00 0.0 0.0 0.0 750 12.3 1.16 8.4 85.1 3.1 1.5
30
2.8 0.7 1.6 550 20.3 12.4 0.75 22.8 27.3 0.6 550 13.2 1.29 9.0 92.3 3.0 1.7
2.8 0.7 1.6 750 21.1 14.5 0.79 23.8 26.8 0.6 750 13.6 1.20 9.6 86.8 3.3 1.7
4.1 2.1 4.9 550 20.7 12.6 0.71 23.1 29.1 0.5 550 13.7 1.31 9.5 93.1 3.1 1.8
4.1 2.1 4.9 750 21.5 14.7 0.75 24.1 28.6 0.6 750 14.1 1.21 10.1 87.5 3.4 1.8
5.5 3.5 8.1 550 21.3 12.9 0.70 23.6 30.5 0.5 550 14.0 1.31 9.7 93.6 3.1 1.8
5.5 3.5 8.1 750 22.1 15.0 0.74 24.6 30.0 0.5 750 14.4 1.21 10.3 87.8 3.5 1.9
40
2.8 0.6 1.4 550 20.8 12.9 0.81 23.5 25.5 0.9 550 15.3 1.33 10.9 95.8 3.4 1.9
2.8 0.6 1.4 750 21.6 15.0 0.86 24.5 25.1 1.0 750 15.8 1.23 11.6 89.5 3.8 2.0
4.1 2.0 4.6 550 21.3 13.1 0.77 23.9 27.6 0.9 550 16.0 1.34 11.5 96.9 3.5 2.0
4.1 2.0 4.6 750 22.1 15.2 0.81 24.9 27.2 0.9 750 16.5 1.24 12.3 90.3 3.9 2.1
5.5 3.2 7.4 550 21.5 13.2 0.75 24.0 28.6 0.8 550 16.3 1.34 11.9 97.5 3.6 2.1
5.5 3.2 7.4 750 22.4 15.3 0.79 25.1 28.1 0.8 750 16.8 1.24 12.6 90.8 4.0 2.1
50
2.8 0.5 1.2 550 21.3 13.5 0.90 24.3 23.7 1.5 550 17.5 1.35 13.0 99.5 3.8 2.2
2.8 0.5 1.2 750 22.1 15.7 0.95 25.3 23.3 1.5 750 18.1 1.25 13.8 92.3 4.2 2.3
4.1 1.7 3.9 550 21.5 13.5 0.84 24.3 25.5 1.3 550 18.4 1.36 13.8 100.9 4.0 2.3
4.1 1.7 3.9 750 22.3 15.7 0.89 25.4 25.1 1.4 750 18.9 1.26 14.6 93.4 4.4 2.4
5.5 2.8 6.5 550 21.6 13.5 0.82 24.4 26.4 1.2 550 18.8 1.36 14.2 101.7 4.0 2.4
5.5 2.8 6.5 750 22.5 15.7 0.87 25.4 26.0 1.3 750 19.4 1.26 15.1 93.9 4.5 2.4
60
2.8 0.3 0.7 550 20.6 13.6 0.99 24.0 20.8 2.0 550 19.8 1.37 15.2 103.4 4.2 2.5
2.8 0.3 0.7 750 21.5 15.8 1.05 25.0 20.4 2.1 750 20.4 1.27 16.1 95.2 4.7 2.6
4.1 1.5 3.5 550 21.1 13.6 0.93 24.3 22.7 1.8 550 20.8 1.38 16.1 105.0 4.4 2.6
4.1 1.5 3.5 750 22.0 15.9 0.99 25.3 22.3 1.9 750 21.4 1.28 17.1 96.5 4.9 2.6
5.5 2.6 6.0 550 21.3 13.6 0.90 24.4 23.6 1.6 550 21.3 1.39 16.6 105.9 4.5 2.7
5.5 2.6 6.0 750 22.2 15.9 0.96 25.4 23.2 1.7 750 22.0 1.28 17.6 97.1 5.0 2.7
70
2.8 0.3 0.7 550 19.6 13.4 1.11 23.4 17.7 2.7 550 22.1 1.40 17.3 107.2 4.6 2.8
2.8 0.3 0.7 750 20.4 15.6 1.17 24.4 17.4 2.8 750 22.8 1.29 18.4 98.2 5.2 2.8
4.1 1.4 3.2 550 20.3 13.5 1.04 23.8 19.5 2.4 550 23.2 1.42 18.3 109.0 4.8 2.9
4.1 1.4 3.2 750 21.1 15.7 1.10 24.8 19.2 2.5 750 23.9 1.31 19.4 99.5 5.3 2.9
5.5 2.4 5.5 550 20.6 13.6 1.00 24.0 20.5 2.1 550 23.8 1.43 18.8 110.0 4.9 3.0
5.5 2.4 5.5 750 21.4 15.8 1.06 25.0 20.1 2.2 750 24.5 1.32 20.0 100.2 5.4 3.1
80
2.8 0.2 0.5 550 18.4 13.1 1.24 22.7 14.8 3.2 550 24.3 1.45 19.3 111.0 4.9 3.0
2.8 0.2 0.5 750 19.2 15.2 1.31 23.6 14.6 3.3 750 25.1 1.34 20.5 101.0 5.5 3.1
4.1 1.2 2.8 550 19.1 13.3 1.16 23.1 16.5 3.0 550 25.5 1.49 20.3 112.9 5.0 3.1
4.1 1.2 2.8 750 19.9 15.4 1.23 24.1 16.2 3.1 750 26.3 1.38 21.5 102.4 5.6 3.2
5.5 2.2 5.1 550 19.5 13.4 1.12 23.3 17.3 2.7 550 26.0 1.52 20.7 113.8 5.0 3.2
5.5 2.2 5.1 750 20.3 15.5 1.19 24.3 17.0 2.9 750 26.8 1.40 22.0 103.1 5.6 3.3
85
2.8 0.2 0.5 550 17.8 12.9 1.32 22.3 13.5 3.6 550 25.4 1.49 20.2 112.7 5.0 3.1
2.8 0.2 0.5 750 18.5 15.0 1.40 23.3 13.3 3.7 750 26.2 1.38 21.4 102.3 5.6 3.2
4.1 1.15 2.7 550 18.5 13.1 1.24 22.7 15.1 3.3 550 26.5 1.55 21.1 114.6 5.0 3.3
4.1 1.15 2.7 750 19.2 15.2 1.31 23.7 14.8 3.5 750 27.3 1.43 22.4 103.7 5.6 3.3
5.5 2.1 4.9 550 18.9 13.2 1.20 22.9 15.9 3.1 550 27.0 1.59 21.5 115.5 5.0 3.4
5.5 2.1 4.9 750 19.6 15.3 1.26 23.9 15.6 3.2 750 27.9 1.47 22.8 104.4 5.6 3.5
90
2.8 0.2 0.5 550 17.2 12.7 1.40 21.9 12.3 4.1 550 26.4 1.54 21.0 114.5 5.0 3.3
2.8 0.2 0.5 750 17.8 14.8 1.48 22.9 12.1 4.3 750 27.2 1.42 22.4 103.6 5.6 3.4
4.1 1.1 2.5 550 17.9 12.9 1.31 22.3 13.7 3.8 550 27.5 1.61 21.9 116.3 5.0 3.4
4.1 1.1 2.5 750 18.6 15.0 1.38 23.3 13.4 3.9 750 28.4 1.49 23.2 105.0 5.6 3.5
5.5 2.0 4.6 550 18.2 13.0 1.27 22.6 14.4 3.5 550 28.0 1.66 22.3 117.2 5.0 3.5
5.5 2.0 4.6 750 19.0 15.2 1.34 23.5 14.2 3.6 750 28.9 1.53 23.6 105.7 5.5 3.6
100
2.8 0.2 0.5 550 15.9 12.3 1.58 21.3 10.1 4.5
550 0.0 0.0 0.0 0.0 0.0 0.0
2.8 0.2 0.5 750 16.5 14.3 1.67 22.2 9.9 4.7
750 0.0 0.0 0.0 0.0 0.0 0.0
4.1 1.1 2.5 550 16.6 12.5 1.48 21.6 11.2 4.3
550 0.0 0.0 0.0 0.0 0.0 0.0
4.1 1.1 2.5 750 17.2 14.6 1.56 22.6 11.0 4.5
750 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.9 4.4 550 16.9 12.6 1.43 21.8 11.8 4.2
550 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.9 4.4 750 17.6 14.7 1.51 22.8 11.6 4.3
750 0.0 0.0 0.0 0.0 0.0 0.0
110
2.8 0.1 0.2 550 14.7 12.0 1.79 20.9 8.3 5.4
550 0.0 0.0 0.0 0.0 0.0 0.0
2.8 0.1 0.2 750 15.3 13.9 1.89 21.8 8.1 5.6
750 0.0 0.0 0.0 0.0 0.0 0.0
4.1 0.9 2.1 550 15.3 12.1 1.67 21.1 9.2 5.2
550 0.0 0.0 0.0 0.0 0.0 0.0
4.1 0.9 2.1 750 15.9 14.1 1.77 22.0 9.0 5.4
750 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.7 3.9 550 15.6 12.2 1.62 21.2 9.7 5.0
550 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.7 3.9 750 16.3 14.2 1.71 22.1 9.5 5.2
750 0.0 0.0 0.0 0.0 0.0 0.0
120
2.8 0.1 0.2 550 13.8 11.5 2.03 20.8 6.8 6.3
550 0.0 0.0 0.0 0.0 0.0 0.0
2.8 0.1 0.2 750 14.4 13.4 2.14 21.7 6.7 6.6
750 0.0 0.0 0.0 0.0 0.0 0.0
4.1 0.8 1.8 550 14.3 11.8 1.90 20.8 7.5 6.1
550 0.0 0.0 0.0 0.0 0.0 0.0
4.1 0.8 1.8 750 14.8 13.7 2.01 21.7 7.4 6.3
750 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.6 3.7 550 14.5 11.9 1.83 20.8 7.9 5.9
550 0.0 0.0 0.0 0.0 0.0 0.0
5.5 1.6 3.7 750 15.1 13.9 1.94 21.7 7.8 6.1
750 0.0 0.0 0.0 0.0 0.0 0.0
Interpolation is permissible; extrapolation is not.
All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating.
AHRI/ISO certi ed conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.
Table does not re ect fan or pump power corrections for AHRI/ISO conditions.
All performance is based upon the lower voltage of dual voltage rated units.
Operation below 40°F EWT is based upon a 15% methanol antifreeze solution.
Operation below 60°F EWT requires optional insulated water/refrigerant circuit.
See performance correction tables for operating conditions other than those listed above.
For operation in the shaded areas, please see the Performance Data Selection Notes.