Bryant 619FNF Air Conditioner User Manual


 
—2—
INSTALLATION
I. STEP 1 — COMPLETE PRE-INSTALLATION CHECKS
A. Unpack Unit (See Fig. 1)
Move the unit to final location. The grille panel and the
remote control are packed separately for maximum protec-
tion. Remove unit from carton, being careful not to lift the
unit by the condensate drain discharge pipe or by the refrig-
erant connections. Handle by the four corners of the unit.
See Table 1 for field-supplied installation materials required
for installation.
B. Inspect Shipment
File a claim with the shipping company if shipment is dam-
aged or incomplete. Check the unit nameplates to ensure
units match job requirements.
C. Consider System Requirements
Consult local building codes and NEC for special installation
requirements. Use only designated indoor units with outdoor
units. See Tables 2-4B.
See Fig. 2 for unit dimensions. Allow sufficient space for air-
flow clearance, wiring, refrigerant piping, and servicing
units.
Avoid mounting the unit in areas that are:
exposed to direct sunlight
too close to heat sources
damp or in areas exposed to water
located in areas that could obstruct air circulation, such
as near curtains or furniture
Table 1 — Field-Supplied Installation Materials
LEGEND
Table 2 — Matching Indoor Units to Outdoor Units*
*All units use R-410A refrigerant only.
Table 3 — AccuRator* Control Sizes and Refrigerant Charge Requirements
*AccuRator controls are for outdoor units. See the outdoor installation instructions for more information.
†The outdoor unit is either fully charged or under charged from the factory.
NAME SPECIFICATIONS
Connection Pipe
619FNF018,024/FNQ01824:
5
/
8
in. (Mixed Phase)/
3
/
8
in. (Liquid)
619FNF, FNQ03036:
3
/
4
in. (Mixed Phase)/
3
/
8
in. (Liquid)
Wall Sleeve
Wall Cap
Finishing Tape PVC Film
Fastening Tape
Tube Insulation
Drain Hose 1 in. ID
Sealer Putty
Outdoor Power Supply Cable
619FNF018-03036: AWG 14
619FNQ01824-03036: AWG 12
Control Wire Electrical Connecting Cable
Between Indoor and Outdoor Unit
Cable Type: AWG 22 synthetic rubber insulation with
Neoprene coating, according to NEC codes.
Wire Nuts
Conduit
AWG American Wire Gage
NEC National Electrical Code
SYSTEM
TYPE
SYSTEM SIZE
OUTDOOR
UNIT
INDOOR UNIT
MODEL NUMBER
INDOOR UNIT
GRILLE ITEM NUMBER
Cooling Only
018 538ENF018000 619FNF018000 619FN9005
024 538ENF024000 619FNF024000 619FN9006
030 538ENF030000 619FNF030360 619FN9006
036 538ENF036000 619FNF030360 619FN9006
Cooling with
Electric Heat
018 538ENF018000 619FNQ018240 619FN9006
024 538ENF024000 619FNQ018240 619FN9006
030 538ENF030000 619FNQ030360 619FN9006
036 538ENF036000 619FNQ030360 619FN9006
Heat Pump
018 538QNF018000 619FNQ018240 619FN9006
024 538QNF024000 619FNQ018240 619FN9006
030 538QNF030000 619FNQ030360 619FN9006
036 538QNF036000 619FNQ030360 619FN9006
SYSTEM
TYPE
SYSTEM
SIZE
COOLING
ACCURATOR
HEATING
ACCURATOR
ACCURATOR
TYPE
FACTORY
CHARGE† (lb)
ADDITIONAL FIELD
CHARGE REQUIRED† (lb)
Cooling Only
018 0.049 B 4.8 0.0
024 0.057 B 5.3 1.2
030 0.061 B 5.0 3.0
036 0.074 B 7.0 2.3
Cooling with
Electric Heat
018 0.049 B 4.8 0.0
024 0.057 B 5.3 1.2
030 0.061 B 5.0 3.0
036 0.074 B 7.0 2.3
Heat Pump
018 0.051 0.046 B 5.5 0.0
024 0.055 0.053 B 6.9 0.0
030 0.063 0.055 B 10.7 1.8
036 0.07 0.063 B 10.5 0.0