Brother BAS-311H Sewing Machine User Manual


 
5. USING THE OPERATION PANEL (BASIC OPERATIONS)
32
BAS-311H
Parameter Setting range and initial value Display
Lo1-Lo9
(Initial values: Lo4)
The starting-up speed at the sewing start can
be adjusted.
* The smaller the number, the slower the start.
* This is used to stop the thread from pulling
out at the sewing start, and at times when
skipped stitches might easily occur.
Lo1 Lo2 Lo3 Lo4 Lo5 Lo6 Lo7 Lo8 Lo9
Sewing speed
for 1st stitch
200 200 300 400 400 400 400 600 800
Sewing speed
for 2nd stitch
200 300 400 400 500 600 800 1000 1200
Sewing speed
for 3rd stitch
300 400 500 600 800 1000 1200 1600 *1
Sewing speed
for 4th stitch
500 600 700 900 1200 1400 *1 *1 *1
Slow start
pattern
*1 Sewing will be carried out at the sewing speed which is set by the parameters.
Counter
Refer to “5-2-3. Using the production counter”.
Split No.
Refer to “5-2-4. Split number setting method”.
Thread
wiping
ON, OFF
(Initial setting is “ON”.)
Initial value
3076B
(sti/min)
3158B