Bosch Appliances DS7400XI Home Security System User Manual


 
DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 61
10.36 Octal Relay Module Output Programming (continued)
10.36.2 Follow System Wide Event: Program Addresses (2740-2771)
To program an Octal Relay Module for Follow System Wide Event, follow the steps below.
1. Select Octal Relay to program.
2. Program Data Digit 1 of Program Address A as 2 for Follow System Wide Event.
3. Program Data Digit 2 of Program Address A for the desired function.
4. Program Data Digit 1 and 2 of Program Address B for the desired function.
Once both Address A and Address B have been programmed, proceed to program the next Octal Relay.
For Octal Relay Partition Assignment, see section 10.36.5.
0 1 2
SELECT OPTION DD 2
3Follows
Disabled
Burglar Alarm
Fire Alarm
Octal
Relay
#
DS7488-1
Address
A
DS7488-1
Address
B
1
2
3
4
5
6
7
8
2740 2741
2742 2743
2744 2745
2746 2747
2748 2749
2750 2751
2752 2753
2754 2755
2756 27579
10
11
12
13
14
2758 2759
2760 2761
2762 2763
2764 2765
2766 2767
2768 2769
2770 2771
15
16
12
Data Digit
Program Address B
12
Data Digit
2
Program Address A
DD
0 0Disabled
AC Power Fail
Low Battery
Communicator Failure
System Fault*
Keypad Supervision Fault
Multiplex Bus Fault
0 1
0 2
0 3
0 4
0 5
0 6
SELECT OPTION DD 1 & 2
Aux Power Fault
Fire Zone Trouble
Supervisory
0 8
0 9
0*0
Duress 0*2
Battery Test
0*3
Zone Trouble
0*1
0*4Future Selection
0*5
Future Selection
RF Receiver Fault
0 7
*System Faults include:
RAM fault
ROM fault
Bell/Line Monitor fault (DS7420i)
Line 1 fault
Line 2 fault
Bell fault
Aux. Power fault
Octal Relay fault
Serial Module fault (DS7412)
Serial Transmit fault
Serial Receive fault
Aux. Relay fault
DS7416i Communication fault
RF Receiver Tamper
RF Receiver Jammed
RF Receiver Trouble
Printer Off-line