Bosch Appliances DS7400XI Home Security System User Manual


 
Page 36 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide
Step 2: Assigning a Zone Function to the Zone
In this step, a Zone function is assigned to the Zone.
10.3 Zone Programming: Program Addresses (0031-0278)
In Zone Programming, each zone is defined according to its input (single or multiple zone input, or a DS7465) and its Zone Function
(1-30) or Output Function (1-24). The DS7465’s relay is the only device that will follow the output functions; its input loop will follow a zone
function. All single and multiple zone inputs will follow a zone function. See section 6.3 for further details.
Data Digit
1
2
1
2
3
4
5
6
7
8
0031
0032
0033
0034
0035
0036
0037
0038
0039-0278
01
02
03
04
05
06
07
08
00
Zone Number Address
Zone
Function
Default
Hint:
Address = Zone Number + 30
Options
Disable azone
Enter a Zone Function Value
Zone
Functio
n
Value
00
01-30
T
he DS7465 occupies two zones. The odd numbered
z
one of the zone pair is the input zone. The even
n
umbered zone of the zone pair is the output relay.
T
he output follows an output function.
9-248