Report Programming (Continued)
10.28 Phone/DS7416i Routing Control: Program Addresses (3153-3154)
If address 3155 is programmed to “Try DS7416i first”, the following addresses can be used to control report routing. If address 3155
is set to “Send alarms via both DS7416i and digital”, this will force alarms to go to the phone even if the Phone/DS7416i report
routing for alarms does not specify phone usage.
Phone/DS7416i report routing (3153).
First digit: Open and Close Reports.
Second digit: Phone First count. Number of attempts before trying the DS7416i:
This value is used to control the number of attempts made on the phone line before switching to the DS7416i. This value is only
referenced if the “Use Phone”, “Use DS7416i”, and “Try Phone First” options are all selected. If the value is less than or equal
to 2, or more than 5, two attempts will be made on the phone before trying the DS7416i if the Phone First option is selected.
Use Phone
Use Either
Try Phone First
Use Both
1 2 7 *1 *5
Select Options
Enter the DD as a:
3
Data Digit
12
DD
0 Attempts
1 Attempt
2 Attempts
3 Attempts
1
2
3
4 Attempts
5 Attempts
6 Attempts
7 Attempts
4
5
6
7
8 Attempts
9 Attempts
10 Attempts
11 Attempts
8
9
*0
*1
12 Attempts
13 Attempts
14 Attempts
15 Attempts
*2
*3
*4
*5
Select Option DD DD DDSelect OptionSelect Option Select Option
0
Use Phone
Use Either
Try Phone First
Use Both
1 2 7 *1 *5
Select Options
Enter the DD as a:
3
Use Phone
Use Either
Try Phone First
Use Both
1 2 7 *1 *5
Select Options
Enter the DD as a:
3
Data Digit
12
Second digit: Zone Alarm, Zone Restoral,
and Zone Trouble Reports.
Phone/DS7416i report routing and Phone First count (3154)
First Digit: System Reports.
Use DS7416i
Use DS7416i
Use DS7416i