Beckett 7600 Boiler User Manual


 
24
CONTINUED FROM PREVIOUS PAGE
Control Wiring (Option 2): 7600A only
1. Set “DHWP on ZR” (see programming section for instructions)
2. Set “C1 on BOTH” (see programming section for instructions)
3. Circulator-on delay will affect all zones. Circulator-off delay will have no effect.
4. 24 VAC zone valves cannot be powered directly with the 7600A. Add an
additional transformer as shown for every two or less valves.
5. Ensure there are no jumpers between the terminals of the zone valves.
TH/
TR
TR
TW
ZONE 1
LOW VOLTAGE
THERMOSTAT
ZONE 1
24 VAC
ZONE VALVE
SK10047
L2 L1 C1 C2 ZC ZR B1 B2
NEUTRAL
HOT
120 VAC
BLACK
WHITE
CIRCULATOR
120 VAC
GENERAL
CIRCULATOR
TR
TH
Honewell
V8043F
ZONE
RELAY
T
T
1/H
2/N
3
4
5
6
DHW ZONE
24 VAC
ZONE VALVE
Y
RR
Y
ZONE 3*
LOW VOLTAGE
THERMOSTAT
ZONE 3*
24 VAC
ZONE VALVE
Honewell
V8043E, V8044E
Taco
550
ZONE 2
24 VAC
ZONE VALVE
ZONE 2
LOW VOLTAGE
THERMOSTAT
THTR
DHW
LIMIT
CONTROL
Honeywell
V8043F
MTR
TH/
TR
MTR
MTR
40 VA
TRANSFORMER
32
MTR
1
FIELD/MFR.
SUPPLIED
SERVICE
SWITCH
120 VAC
BURNER OR
GAS IGNITION
SYSTEM
40 VA
TRANSFORMER
Figure 17 (continued) - 7600A/B alternate multi-zone
connections with Indirect Domestic Hot Water (DHW)
* Additional zones can be added by duplicating the
plumbing and wiring of zone 3, adding additional
transformers as needed.