Avalon Stoves 700 B-VENT Stove User Manual


 
PAGE 6 STOVE INSTALLATION - For qualified installers only!
Installation Preparation
! This appliance must be installed in accordance with all local codes, if any; if not, follow ANSI
Z223.1 and the requirements listed in this manual. Failure to follow all of the requirements
may result in property damage, bodily injury, or even death.
! Notify your insurance company before hooking up this heater.
! The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid Ð the qualified installer should follow the
procedure best suited for the installation.
Items Required for Installation
¥ B-Vent System
¥ Brass, Black, or Cast Legs or Pedestal
¥ Gas Hookup Equipment
Items Packed with the
Chelan (700) B-Vent
¥ Gas Inlet (3/8" Pipe)
¥ Propane Conversion Kit
¥ Owner's Manual
¥ Log Set (2 Logs, 2 Twigs, Embers)
¥ 2 Leveling Bolts (3/8"-16 x 3" Carriage Bolts - not used for stove installations)
Order of Installation
1 Attach the legs or pedestal (see page 26)
2 If the heater is to use propane, install the propane conversion kit (see page 31)
3 Position the heater, use floor protection if needed
4 Attach any optional equipment.
5 Connect the gas line. Connect the gas vent.
6 Follow the instructions under "Finalizing the Installation" on pages 14 and 15.
Stove Clearances
10" Min.
4" Min.
45¡
Straight Installations Corner Installations
When installed with this clearance, the
vent is 13-1/2" from the wall.
4" Min.
When installed with
this clearance, the
vent is 6-1/4" from the
back wall, 19-1/2"
from the side wall.