E6581301
11
K-38
[30] My function [5/5] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
setting unit
(Panel/Communi
Default
setting
running
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0962 Analog input function target 21
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0964
0~10 1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0965 Monitor output function target 11
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0966
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0967
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0968
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0969
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0970
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0971
1/1 2000 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0972
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
Virtual input terminal selection 1
H
Virtual input terminal selection
H
Virtual input terminal selection
H
Virtual input terminal selection
H
0977 My function selection
1:My function + permission signal
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
*1: For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2: For the adjustment range, see the table on page K-43.
[31] Travenirse function Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
setting unit
(Panel/Communi
Default
setting
running
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0980 Traverse selection
1/1 0 Disabled Ɣ/Ɣ - Ɣ Ɣ *1
H
Traverse acceleration time
H
Traverse deceleration time
H
H
*1: For details, refer to Instruction Manual (E6581337) specified in Section 6.42.