E6581301
11
K-24
[25] Protection functions [2/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
setting unit
(Panel/Communi
Default
setting
running
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
Abnormal speed detection time
H
0623
Overspeed detection frequency
0.00:Disabled, 0.01~30.0Hz 0.01/0.01 0.0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 13
H
0624
Overspeed detection frequency
0.00:Disabled, 0.01~30.0Hz 0.01/0.01 0.0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 13
H
Undervoltage detection level
H
Overvoltage limit operation level
H
0627 Undervoltage trip selection
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 15
H
0628
Undervoltage (trip alarm)
0.01~10.00 sec. 0.01/0.01 0.03 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 15
H
0629
55~100% 1/1 75 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 16
H
Braking answer waiting time
0.0:Disabled, 0.1~10.0 sec.
H
0631 Temperature detection
1:Estimation of temperature
1/1 0 Disabled - - - - 5. 14
H
0632
0.00᳸2.50 s 0.01/0.01 0.00 Disabled Ɣ/Ɣ -/- - - 6.17
H 0633
VI/II analog input wire breakage
detection level
0:None
1~100%
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 18
H
0634
Annual average ambient
temperature (calculation for part
replacement alarms)
2:+11~+20°C
3:+21~+30°C
4:+31~+40°C
5:+41~+50°C
1/1 3 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 19
H
0635
Rush current suppression relay
activation time
0.0~2.5 sec. 0.1/0.1 0.0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 20
H
H
H
0639
Braking resistance overload
(10 times of rated torque)
0.1~600.0 sec. 0.1/0.1 5.0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 5. 19
H
0640
out detection current level
10~150 1/1 100 Disabled - - Ɣ - 6. 29
H
0641
out detection time (for PM
0.1/0.1 0.0 Disabled - - Ɣ - 6. 29
H
0643
Brake-equipped motor restart
condition selection
Default (no waiting time for frequencies of 10Hz
and less)
1:Conditional (no waiting time for frequencies of
20Hz and less)
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 23
H
0647
Control power supply backup
option failure monitoring
Control power supply not backed up
1:Control power supply backed up (alarm in the
event of a failure)
2:Control power supply backed up (tripping in the
event of a failure)
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 33. 24
*1: For details, refer to Instruction Manual (E6581339) specified in Section 6.42.