4
USER INSTRUCTIONS
1.7 The manufacturer considers the full outer casing of this
stove to be a working surface which becomes hot when the
stove is lit. A suitable guard is recommended to protect
young children, the aged and the infirm.
1.8 This stove must only be operated with the door secured
firmly in position. If any cracks appear in the glass the
appliance must not be used until the glass panel is replaced.
1.9 Do not attempt to burn rubbish in this stove.
1.10 Do not hang curtains above the stove.
You must leave 300mm (1’) clearance between the stove
and any curtains at either side.
1.11 Any combustible shelves or surrounding furniture must be
fitted in accordance with the minimum dimensions detailed
in Diagram 1.
150
225
150
1
AR0552
1.12 Following home improvements carried out after installation
of this stove (e.g. the fitting of double glazing) contact a
competent service engineer to carry out relevant spillage
checks etc.
1.13 Quote the Model and Serial Number found on the data
badge at the back of the stove in all correspondence.
1.14 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco retailer. Please
consult your Gazco retailer if you have any questions. In all
correspondence always quote the model no. and serial no.
Please ensure the commissioning checklist is completed
by your installer as this is a requirement of your
Guarantee.
1. GENERAL
In the event of a gas escape, or if you can smell gas,
please take the following steps:
—Immediately turn off the gas supply at the meter/
emergency control valve.
—Extinguish all sources of ignition.
—Do not smoke.
—Do not operate any electrical light or power switches
(On or Off).
—Ventilate the building(s) by opening doors and
windows.
—Ensure access to the premises can be made.
Please report the incident immediately to the National
Gas Emergency Service Call Centre on 0800 111 999
(England, Scotland and Wales) 0800 002 001
(N. Ireland) or in the case of LPG, the gas supplier whose
details can be found on the bulk storage vessel or
cylinder.
The gas supply must not be used until remedial action
has been taken to correct the defect and the installation
has been recommissioned by a competent person.
1.1 Installation and servicing must only be carried out by a
competent person whose name appears on the Gas Safe
register. To ensure the engineer is registered with Gas Safe
they should possess an ID Card carrying the following logo:
1.2 This appliance is suitable for use in G.B. and I.E. using
Natural Gas at a supply pressure of 20mbar or LPG at a
supply pressure of 29mbar (Butane) or 37mbar (propane).
1.3 The installation shall also be completed in accordance with:
—The Building Regulations issued by The Department of
The Environment.
—The Building Standards (Scotland) Regulations issued by
the Scottish Development Department.
—For Republic of Ireland, reference should be made to the
relevant standards governing installations (IS813:1996).
1.4 Read all these instructions before commencing installation.
1.5 This appliance must be installed in accordance with the
rules in force and only used in a sufficiently ventilated
space.
1.6 Ensure that curtains are not positioned above the stove, and
that there is a clearance of at least 300mm between the
sides of the stove and any curtains.