White Rodgers HC-TST501CMMS Thermostat User Manual


 
Advanced Installer Confi guration Menu
Dipswitch*
Dip Switch Indications Comments
Cool Airfl ow XXXXCFM Airfl ow Dipswitch Settings
Heat Rise Nom, Nom+10 Heat Rise Airfl ow Settings
Hi Heat Adj -15%, -7%, 0%, 7%, 15% High Heat Airfl ow Settings
Lo Heat Adj -15%, -7%, 0%, 7%, 15% Low Heat Airfl ow Settings
Fan Spd Select Lo, Hi Fan Speed Settings
AC-HP Adj -10%, 0%, 10% Heat Pump AC Airfl ow Settings
On-Demand Dehum On, Off Dehumidifi cation Settings
Test Mode Off, 40% (70%), 100% Test Mode Settings
AC HP Stg Mult NA, 50%, 75% Heat Pump AC Stage Multiplier
* Dipswitch status is not required when the system is set up for 4-wire
communications. It is only displayed when a conventional 24V thermostat
input is active.
Select continuous FAN speed.
Default is Medium. It can be set to High,
Medium or Low. In High, the fan will run
at the highest speed when FAN key is
selected to On. In high, the fan speed
will be at high speed, in medium the
fan speed will be approximately 60% of
high, and in low the fan speed will be
approximately 30% of high.
Select program days per week.
Scrolling message will show
“PROGRAM TYPE”. Default is 7 Days
to indicate individual day programming.
It can be changed to 0 Days to indicate
no programs will be run. When set for
7 Days, the thermostat will follow the
factory program or the program that you
entered.
Select Energy Management Recovery.
Scrolling Message will show “ENERGY
MANAGEMENT RECOVERY”. (Will
not appear if Program days per week is
set to 0 Days.) When selected On, the
thermostat will begin heating or cooling
early to have the temperature reach the
program setpoint at the program period
start time.
Example: The heating program is 65° at
night and 70° at 7 AM for the Morning
period. The building temperature is 65°,
a difference of 5°. Allowing 5 minutes
per °F rise, the thermostat will begin the
system at 6:35 AM to reach 70° at 7 AM.
1
2
1
2
Thermostat Setup
1
2
Furnace User Menus (Cont.)
Unit Info
Parameter Indications Comments
Model Number XXXX-XXXXXXXXXXXXXXXX Unit Model Number
Serial Number XXXXXXXXXXXXXXXXXXX Unit Serial Number (Not available if
control is replaced)
Software Vers XXXXXX Control Software Version
Setup
Parameter Options Comments
Heat Rise Adjust 55F, 65F Change airfl ow to adjust heat temperature rise
Min Heat Adj % -15, -7, 0, 7, 15 Selectable Airfl ow Adjustments at 40% Firing Rate
Max Heat Adj % -15, -7, 0, 7, 15 Selectable Airfl ow Adjustments at 100% Firing Rate
Supply Air Sens On, Off Factory default is On, if Sensor is not installed
turn Off
Reset All Dfl ts No, Yes Resets the Furnace to the Factory Default
Confi guration by selecting Yes