White Rodgers 1F92W-51 Thermostat User Manual


 
32
cycles are too long, press
TIME
BACK
to decrease
the cycle time. To set COOL anticipation, press
SET
CLOCK
and
SET
DAY
at the same time again. The
display will show COOL 14 (factory
preprogrammed cooling anticipation). Use
TIME
FWD
and
TIME
BACK
to adjust anticipation. To set
AUXILIARY heat anticipation (not applicable to
multi-stage use), press
SET
CLOCK
and
SET
DAY
at the
same time again. The display will show AUX 8
(factory preprogrammed auxiliary anticipation).
Use
TIME
FWD
and
TIME
BACK
to adjust anticipation.
Press
RUN
PRGM
to return to your program.
LOW BATTERY INDICATOR — The word BAT
will flash on the display if the battery is low and
should be replaced. When BAT is displayed
continuously (non-flashing), 24 VAC power is
not being supplied and the thermostat is work-
ing on battery power only.
COMPRESSOR SHORT CYCLE PROTEC-
TION — To protect your compressor from poten-
tial damage due to rapid cycling, this thermostat
has a built-in delay of 5 minutes between cooling
cycles. The following may cause a time delay in
COOL or HEAT:
a) Return of power after a momentary power
outage.
b) Pressing
SYSTEM
HEAT-OFF-COOL-AUTO
to change operating
modes.
c) Pressing or to create a call for
COOL or HEAT too soon after a previous
call.
During lockout in the COOL mode, the blower
will operate, but compressor operation will be
delayed.