White Rodgers 1F92W-51 Thermostat User Manual


 
30
AUTOMATIC CHANGEOVER (OFF)
Switch #1 set at installation (DO NOT CHANGE)
Switch #2 set at installation (DO NOT CHANGE)
Switch #3 set at installation (DO NOT CHANGE)
Switch #4 OFF
TWO HOUR TEMPERATURE OVERRIDE
Press
or until the display shows the
temperature you want. The thermostat will over-
ride current programming and keep the room
temperature at the selected temperature for two
hours. After two hours, the thermostat will auto-
matically revert to the program.
HOLD TEMPERATURE — The thermostat can
hold any temperature within its range for an
indefinite period, without reverting to the pro-
If the automatic changeover feature is enabled,
and you wish to disable it, press
SYSTEM
HEAT-OFF-COOL-AUTO
until
thermostat is OFF. Then, remove the thermo-
stat body from the wall. Move the switch to the
ON position (see figure at right). Leave the
battery out of the thermostat for at least two
minutes, to allow the thermostat to reset itself.
DO NOT MOVE ANY OTHER OPTION
SWITCH, as it may affect thermostat operation.
Replace the battery, re-program the thermostat
if necessary, put the thermostat back on the
wall, and use
SYSTEM
HEAT-OFF-COOL-AUTO
to set the thermostat as
desired.
ON
1234