CGi-4E Gas-Fired Water Boiler — Boiler Manual
Figure 29 Typical main burner flame
Check burner flames
Viewpilotandmainamesthroughtheinspectionport
in the base burner shield.
Pilot burner flame (Figure 28)
PROPER pilot flame characteristics
1. Blueame.
2. Inner cone engulfing pilot flame sensor.
3. Pilot flame sensor glowing cherry red.
IMPROPER pilot flame characteristics
1. Overfired — Large flame lifting or blowing
past pilot flame sensor.
2. Underred—Smallame.Innerconenot
engulfing pilot flame sensor.
3. Lackofprimaryair—Yellowametip.
4. Incorrectly heated pilot flame sensor.
Main burner flame (Figure 29)
PROPER main burner flame characteristics
1. Yellow-orangestreaksmayappear(causedby
dust).
(NOTE:TheCGi-4Ewilloperateatlowrefor
the first 60 seconds.)
IMPROPER main burner flame characteristics
1. Overfired — Large flames.
2. Underred—Smallames.
3. Lackofprimaryair—Yellowtippingon
flames (sooting will occur).
Figure 28 Typical pilot burner flame
Start-up — operate boiler (continued)7b