VOLTAGE
TOTAL
KW
NUMBER
OF
ELEMENTS
KW
PER
ELEMENT
AMPERAGE
PER LINE
RESISTANCE
PER
ELEMENT
(OHMS)
1 PH 3 PH
208 18 2 9 87 50 14.42
240 18 2 9 75 44 19.20
480 18 2 9 22 76.80
*220/380
240/415
18 2 9 25 19.20
208 24 2 12 116 68 10.82
240 24 2 12 100 58 14.40
480 24 2 12 29 57.60
*220/380
240/415
24 2 12 34 14.40
208 36 4 9 100 14.42
240 36 4 9 87 19.20
480 36 4 9 44 76.80
*220/380
240/415
36 4 9 50 19.20
208 42 4 10.5 117 12.36
240 48 4 12 116 14.40
480 48 4 12 58 57.60
*220/380
240/415
48 4 12 67 14.40
NOTES:
1. Values in the table are nominal. Tolerance is +/-10 %.
2. Asterisk (*) indicates 3 phase/4wire.
3. Each heater has three internal elements.