Toshiba RAV-SM806KRT-TR Air Conditioner User Manual


 
Ta ˚C
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
Tsc
–0.5
HH
(HH)
H+ (HH)
H (HH)
L+ (H+)
L (H)
L (H)
L (L+)
D
C
B
A
E
F
G
Ta ˚C
(–0.5) –1.0
(0) Tsh
(+0.5) +1.0
(+1.0) +2.0
(+1.5) +3.0
(+2.0) +4.0
L (L+)
L+ (H)
H (H+)
HH
(HH)
H+
(HH)
E
D
C
B
A
No.
6
Item
Fan speed control
Outline of specifications
1) Operation with (HH), (H), (L) or [AUTO] mode is carried
out by the command from the remote controller.
2) When the fan speed mode [AUTO] is selected, the fan
speed varies by the difference between Ta and Ts.
<COOL>
Controlling operation in case when thermo of remote
controller works is same as a case when thermo of the
body works.
If the fan speed has been changed once, it is not
changed for 3 minutes. However when the air volume is
exchanged, the fan speed changes.
When cooling operation has started, select a downward
slope for the fan speed, that is, the high position.
If the temperature is just on the difference boundary, the
fan speed does not change.
Mode in the parentheses indicates one in automatic
cooling operation.
<HEAT>
Value in the parentheses indicates one when thermostat of
the remote controller works.
Value without parentheses indicates one when thermostat
of the body works.
If the fan speed has been changed once, it is not
changed for 1 minute. However when the fan speed I
exchanged, the fan speed changes.
When heating operation has started, select an upward
slope for the fan speed, that is, the high position.
If the temperature is just on the difference boundary, the
fan speed does not change.
Mode in the parentheses indicates one in automatic
heating operation.
In Tc 60°C, the fan speed increases by 1 step.
Remarks
HH > H+ > H > L+ > L >
UL
Wireless type allows HH,
H+, H, L+, L and AUTO.
[HH]
[H+]
[H]
[L+]
[L]
Tc: Indoor heat
exchanger sensor
temperature
FILE NO. SVM-12004
30