Toshiba RAV-SM1100AT-E Air Conditioner User Manual


 
2
Model name
Standard capacity (Note 1) (kW)
Heating low temp. capacity (Note 1) (kW)
Energy consumption effect ratio (Cooling)
Power supply
Electrical
Running current (A)
Power consumption (kW)
characteristics
(Low temp.) (kW)
Power factor (%)
Main unit
Appearance
Ceiling Panel
Model
(Sold separately)
Panel color
Height (mm)
Main unit Width (mm)
Outer
Depth (mm)
dimension
Ceiling panel
Height (mm)
Width (mm)
(Sold separately)
Depth (mm)
Total weight
Main unit (kg)
Ceiling panel
Heat exchanger
Soundproof/Heat-insulating material
Fan
Fan unit Standard air flow High (Mid./Low) (m³/h)
Motor (W)
Air filter
Controller (Sold separately)
Connecting
Gas side (mm)
Liquid side (mm)
pipe
Drain port (Nominal dia.)
Sound level High (Mid./Low) (Note 2) (dB•A)
RAV-SM1101BT-E RAV-SM1401BT-E
Cooling Heating Average Cooling Heating Average
10.0 11.2 12.5 14.0
(2.2 – 11.2) (2.2 – 12.5) (3.0 – 13.2) (3.0 – 16.0)
8.7 11.8
2.81 [C] 3.57 [B] 3.19 2.83 [C] 3.47 [B] 3.15
1 phase 230V (220 – 240V) 50Hz
16.5–15.1 14.6–13.4 20.7–19.0 18.9–17.3
3.56 3.14 4.42 4.03
3.50 4.18
98 98 97 97
Zinc hot dipping steel plate
——
——
320
1340
800
——
——
——
54 54
——
Finned tubu
Inflammable polyethylene foam
Multi-blade fan
1620 1980
120 120
Attached main unit
RBC-AMT21E
Ø15.9 (5/8”)
Ø9.5 (3/8”)
25 (Polyvinyl chloride tube)
42 39 36 44 41 38
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8616 based
on the reference piping 7.5m.
Note 2 : The sound level is measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB