21
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAV-SM561BT-E / SM801BT-E / SM1101BT-E / SM1401BT-E
No.
1
2
3
4
5
6
7
8
Parts name
Fan motor (SM801BT-E)
Fan motor
(SM561BT-E/SM1101BT-E/SM1401BT-E)
Thermo. sensor (TA-sensor)
Heat exchanger sensor (TCJ-sensor)
Heat exchanger sensor (TC-sensor)
Float switch
Drain pump motor
Reactor
Type
ICF-280-120-1
ICF-280-120-2
258 mm
Ø6 mm, 1200 mm
Ø6 mm, 1200 mm
FS-0218-106
ADP-1406
CH-43-2Z-K
Specifications
Output (Rated) 120 W, 220–240 V
Output (Rated) 120 W, 220–240 V
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
10 mH, 1 A
6-2. Outdoor Unit
RAV-SM560AT-E
No.
1
2
3
4
5
6
7
8
9
10
11
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect)
4-way valve solenoid coil
Compressor thermo. (Protection)
Type
ICF-140-43-1
DA130A1F-23F
CH-57
—
—
—
—
STF-0108G
US-622
Specifications
Output (Rated) 40 W
3 phase, 4P, 1100 W
10 mH, 16A
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C
RAV-SM800AT-E
No.
1
2
3
4
5
6
7
8
9
10
11
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect))
4-way valve solenoid coil
Compressor thermo. (Protection)
Type
ICF-140-63-1 or ICF-140-63-2
DA220A2F-20L
CH-47
—
—
—
—
DKV-M0ZS743B0
US-622
Specifications
Output (Rated) 63 W
3 phase, 4P, 1600 W
8 mH, 16 A
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C