Sterling Plumbing 882.00253.00 Septic System User Manual


 
4 –Pump 38-Station Controllers Chapter 4: Operation 33 of 44
Figure 15: Transfer To Standby Pump Button
Note: When you enter the second pump number, the controller checks to make sure that
both pumps are offline and that the standby pump has no stations assigned to it.
If these conditions are not all met, error messages appear on the screen instead
of MOVE button. If you get an error message, first check to make sure that you
have entered the correct numbers and reenter if necessary. If another error
occurs, see the Standby Pump Errors section on page 33.
7. Touch the MOVE button. When transfer is complete, stations moved will appear on
the screen.
8. Touch RETURN, to return to the “Pump Setup” screen.
9. Put the standby pump online by briefly touching its icon. The icon changes color to
show the new status, and the system begins using the pump. In addition, all “Station
Operator” and “Station Setup” screens show the new pump assignment.
Standby Pump Errors
If the error message tells you to disable the source pump and/or the standby pump, touch
RETURN at this screen, then PUMP STATUS at the “Pump Setup” screen. Take the pumps
offline and then return to the “Transfer to Standby Pump” screen.
If the error message tells you that the standby pump has stations assigned, you must either use
a different standby pump or you must remove the pump assignment for all stations assigned
to the standby pump. To remove the assignments, complete the following steps:
1. Touch RETURN at the “Standby Pump” screen, and then touch STATION STATUS.
2. Touch and hold a station icon to get to the “Station Operator” screen.
3. Then touch STATION SETUP to go to the “Station Setup” screen.
4. Use PREVIOUS and NEXT to review all pump assignments.
5. Where necessary, choose ASSIGNED TO PUMP to set station assignments to 0
(unassigned). Then return to the “Transfer to Standby Pump” screen.
6. Touch left side pump value and enter the number of the pump whose hoppers are to be
transferred.
7. Touch right side pump value and enter destination pump number.