10.4 Tubing Length
Install unit within the maximum elevation
different (H) above or below the outdoor
unit and within a tatal tubing length (L)
from the outdoor unit as detailed showed
in Table 4 and Fig.37.
INDOOR
UNIT
Tubing length (L)
OUTDOOR
UNIT
Elevation
difference (H)
Fig. 37
10.5 Accessories
Table 5 listed the accessories supplied with the unit.
Table 4
*1 Standard tubing length is 5.0m.
*2 If total tubing length becomes 5.0m to 20 or 25 or 30m, charge additional refrigerant (R22) according
to table 4 above. No additional charge of compressor oil is necessary.
Model
Max. Allowable Tubing
Length at Shipment
(m)*
1
Limit of Tubing
Length (L)
(m)
Limit of Elevation
Different (H)
(m)
Required Amount of
Additional Refrigerant
(g/m)*
2
C18AP 5.0
7
30
25
C25AP 5.0
7
30
30