Sanyo SAP-K12AP Air Conditioner User Manual


 
10. INSTALL OUTDOOR UNIT
26
10.1 Wiring Instructions for the Outdoor
Unit
1. C9AP, C12AP, C18AP, C25AP
Disassemble the handle on the outdoor
unit right side plate. (Screw x 1pc)
C30AP
Disassemble the front side plate on the
outdoor front side. (Screw x 3pcs)
2. Take off wire clamp, connect and fix
power connect cord to terminal of line
bank. Connect the inter-unit wiring
and power line according to the
drawing on the handle (C9,12,18,25AP)
or front side plate (C30AP).
3. Fix the power connection cable with wire
clamp. (Fig. 24)
Use the wire clamp to fix the
signal control wire, then
connect to the corresponding
connector.
4. Be sure to size each wire allowing approx.
10 cm longer than the required length for
wiring, Store excess wiring inside the
cabinet.
5. When connections are completed, check
that all connections are correct as shown
in the wiring system diagram on the
handle / front side plate.
6. Be sure to ground the unit according to
your local codes.
7. Install back the handle / front side plate.
Fig. 24b (C18AP, C25AP)
1.
2.
Handle
Power
Connection
Wire
Yellow-green
Blue
Black
NOTE
Regulations on wire size differ from locality.
For field wiring requirements, please refer to
your local electrical codes. Make sure that
the installation fully complies with all local
and national regulations.
Installation Service
3
Brown
Wire clamp
Fig. 24a (C9AP,C12AP)
1.
2.
Handle
Wire clamp
Power
Connection
Wire
Yellow-green
Blue
Black
WARNING
Loose wiring may cause the terminal to
overheat or result in unit malfunction.
A fire hazard may also exist. Therefore,
be sure all wiring is tightly connected.
Fig. 24c (C30AP)
Front side
plate
Wire clamp
Power
Connection
Wire
Blue
Black
N(4)
5
Blue
Brown
Yellow-Green
Power
Supply
Wire
3
Brown
N(1)
( Factory
supplied
6m )