Sanyo SAP-K12AP Air Conditioner User Manual


 
9. INSTALL INDOOR UNIT
22
NOTE
1. Drainage hose must be placed at downward
slant downward slant for smooth drainage.
2. Do not wrench, bend or heave the drainage
hose or flood its end by water. (Fig.14)
3. The prolonged drainage hose should be
covered by heat insulation material when
through indoor.
9.1 Install the Rear Panel
9.2 Install the Piping Hole
9.3 Install the Water Drainage Pipe
1. Always mount the rear panel horizontally.
Due to the water tray of indoor unit has been
been adopted the both-way drainage design,
the outlet of water tray should be adjusted
slightly down when installing, that is taking the
outlet of the water tray as the center of a circle,
the included angle between the evaporator and
level should be 0 or more, that is good for
condensing water drainage.
2. Fix the rear panel on the wall with screws.
(Where is pre-covered with plastic granula)
3. Be sure that the rear panel has been fixed
firmly enough to support the weight of an adult
of 60kg, further more, the weight should be
evenly shared by each screw.
Ø55 / Ø70
Outdoor
Indoor
Wall pipe
Seal pad
Protection
sleeve pipe
Fig.13
Flooded
Wrenched
Bent
Fig.14
Left
tubing
Right tubing
Right-rear
tubing
(recommended)
Left-rear
tubing
Fig.12
1. Determine which side of the unit you should
make the hole for tubing and wiring.
(Fig.11,12)
2. Make the piping hole (Ф55 or Ф70) in the wall
at a slight downward slant to the outdoor side.
(Fig.13)
3. Insert the piping-hole sleeve into the hole to
prevent the connection piping and wiring from
from being damaged when passing through
the hole.
Before making the hole, check
carefully that no studs or pipes
are directly run behind the spot
to be cut.
Also avoid areas where electrical
wiring or conduits are located.
Installation Service
Hole Dia.
( K9AP, K12AP K18AP )
Ø 55mm
Hole Dia.
( K25AP, K30AP )
Ø 70mm
Fig.11
Wall
Wall
Mark on the
middle of it
Gradienter
(Rear piping hole)
(Rear piping hole)
Space
to the
wall
150mm
above
Space
to the
wall
150mm
above
Left
φ
55mm
Right
φ
55mm
Wall
Wall
Mark on the
middle of it
Gradienter
Space
to the
wall
150mm
above
Space
to the
wall
150mm
above
Left
Right
(Rear piping hole) φ70mm
Wall-Mounting Plate
90mm
50mm
φ70mm (Rear piping hole)
90mm
50mm
Models: K18AP / K25AP
Wall
Wall
Mark on the
middle of it
Gradienter
Space
to the
wall
150mm
above
Space
to the
wall
150mm
above
Left
φ55/70mm (Rear piping hole)
Right
(Rear piping hole) φ 55/70m
60mm
50mm
Wall
Wall
Mark on the
middle of it
Gradienter
(Rear piping hole)
(Rear piping hole)
Space
to the
wall
150mm
above
Space
to the
wall
150mm
above
Left
φ
55mm
Right
φ
55mm
90mm
40mm
251mm
180mm
184mm
138mm
173mm
130mm
35mm
150mm
Model: K30AP
Models: K12AP
Models: K9AP