Sanyo KGS1411 Air Conditioner User Manual


 
5
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2-2. Outdoor Unit (1)
Outdoor unit CG1411
Control PCB
Part No. CG1411
Controls Microprocessor
Control circuit fuse 115V 5A
Gas Connection
Employed gas Natural Gas (LP)
Gas connection 1/2 Female
Compressor
Type Rotary (Hermetic)
Compressor model C-1R71H2W
Nominal output W 700
Compressor oil … Amount cc SUNISO 4GSD-T … 370
Coil resistance (ambient temp. 68°F (20°C)) C – R: 0.879
C – S: 3.609
Safety devices Type External (OLR)
Overload relay MRA98962-9200
Operating temp. Open °F (°C) 275 ± 9 (135 ± 5)
Close °F (°C) 156 ± 20 (69 ± 11)
Operating amp (ambient temp. 77°F (25°C))
Trip in 6 to 16 sec. at 34A
Run capacitor µF 35
VAC 330
PTC starter Part number 912X24E400XR20-PS2A
Resistance 47
Max voltage 300
Crank case heater
Fan & Fan Motor
Type Propeller
Q’ty … Dia. and length inch. (mm) 1 … 13-25/32 (ø 350)
Fan motor model … Q’ty SB6-11H1P … 1
No. of poles … rpm (115V, High) 6 … 600
Nominal output W 10
Coil resistance (ambient temp. 77°F (25°C)) BLU BRN: 114.0 ± 7%
BLU WHT: 153.4 ± 7%
Safety devices Type Thermostat
Operating temp. Open °F (°C) 266 ± 14 (130 ± 8)
Close °F (°C) 174 ± 27 (79 ± 15) Automatic reclosing
Run capacitor µF 5.0
VAC 220
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch inch (mm) 1/16 (1.3)
Face area ft
2
(m
2
) 2.73 (0.254)
External Finish Acrylic baked-on enamel finish