Sanyo KGS1411 Air Conditioner User Manual


 
2
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are
Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature 70°F D.B.
Outdoor air temperature 47°F D.B. / 43°F W.B.
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor unit KGS1411
Outdoor unit CG1411
Power Source Cooling Heating
Electric power source 115V 60Hz
Employed gas Natural gas (LP)
Performance Cooling Heating
Capacity kW 2.58 4.1 / 2.9 / 1.8
8,800 14,000 / 9,900 / 6,150
Air circulation (High) ft
3
/min (m
3
/min) 282 (8.0) 300 (8.5)
Moisture removal (High) Pints/h 2.2
Electrical Rating Cooling Heating
Available voltage range V 104 – 126
Running amperes A 8.2 5.9
Power input W 900 620
Power factor % 95 91
SEER BTU/W 10.0
Compressor locked rotor amperes A 49
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON / OFF 12 hours, 1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1 (Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment lb. (kg) 1.34 (0.61)
Refrigerant control Capillary tube
Operation sound Indoor: Hi / Me / Lo dB-A 39 / 37 / 34 41 / 38 / 33
Outdoor: Hi dB-A 45 43
Refrigerant tubing connections Flare
Max allowable tubing length at shipment ft. (m) 25 (7.5)
Refrigerant tubing Narrow tube inch (mm) 1/4 (6.35)
diameter Wide tube inch (mm) 3/8 (9.52)
Cooling Heating
Voltage Rating 115V