Sanyo KGS1411 Air Conditioner User Manual


 
6
2-2-2. Outdoor Unit (2)
Outdoor unit CG1411
Burner
Type Ribbon burner
Q’ty … Material, thickness inch (mm) 1 … Stainless steel, 0.0157 (0.4)
Nozzle
Q’ty … Material 1 … Brass
Diameter ø inch (ø mm) 0.0807 (2.05 ± 0.05)
Fan & Fan Motor
Type Sirocco fan
Q’ty … Dia. and length inch (mm) 1 … ø 3.346 (85) and 0.984 (25)
Fan motor model … Q’ty FU2-051FIMP … 1
No. of poles … rpm 2 … (1,300 – 2,900)
Nominal output W 6
Coil resistance (ambient temp. 68°F (20°C)) 21.3
Safety devices Type Thermal fuse
Operating temp. Open °F (°C) 293 (145)
Close
Refrigerant Heater
Case / Coil Aluminum (collapsible forming) / Copper tube
Heat conduction face area ft
2
(m
2
) 1.83 (0.17)
Heat load × 10
–3
BTU/h • ft
2
(m
2
) 7.65 (1.3)
Combination Gas Valve
Type Combination control
Model UP13-27
Coil resistance
Valve (SV1 & SV2 for shut-off)
1600 ± 10%
Valve (PV for control) 87 ± 10%
Igniter
Type Electric sparking
Model IG-XS07-S
DATA SUBJECT TO CHANGE WITHOUT NOTICE.