Sanyo DE Air Conditioner User Manual


 
SUPER ABSORPTIONENVIRONMENTALLY FRIENDLY TECHNOLOGY
Name Lamp color
Running(Operation) indication lamp Red
Stop indication lamp Green
Alarm indication lamp Orange
Remote / Local select button with lamp Red
Mode select button with lamp Red
Data display LED
symbol
Control panel (NE)Foundation dimensional data (NE)
Table 10. Dimensional data
Figure 45. NE-51 Thru NE-82
Model
No.
Weight (kg) Dimensions (mm)
4,200 2,100 2,100 1,896 175 350 900 150 1,200 150 1,000
4,400 2,200 2,200 1,896 175 350 900 150 1,200 150 1,000
5,500 2,700 2,750 2,916 175 350 900 150 1,200 150 1,000
5,700 2,850 2,850 2,916 175 350 900 150 1,200 150 1,000
6,800 3,400 3,400 2,916 175 350 1,100 150 1,400 150 1,200
7,100 3,550 3,550 2,916 175 350 1,100 150 1,400 150 1,200
8,400 4,200 4,200 3,939 175 350 1,100 150 1,400 150 1,200
8,800 4,400 4,400 3,939 175 350 1,100 150 1,400 150 1,200
10,800 5,400 5,400 3,886 200 400 1,200 150 1,500 200 1,300
11,200 5,600 5,600 3,886 200 400 1,200 150 1,500 200 1,300
13,200 6,600 6,600 3,886 200 400 1,250 150 1,550 200 1,350
13,600 6,800 6,800 3,886 200 400 1,250 150 1,550 200 1,350
18,800 9,400 9,400 3,966 130 190 510 1,700 180 2,060 250 1,800
20,400 10,200 10,200 4,508 130 190 510 1,700 180 2,060 250 1,800
21,900 10,950 10,950 5,006 130 190 510 1,700 180 2,060 250 1,800
26,600 13,300 13,300 4,466 140 210 560 1,800 180 2,160 300 1,900
28,500 14,250 14,250 4,966 140 210 560 1,800 180 2,160 300 1,900
30,500 15,250 15,250 5,491 140 210 560 1,800 180 2,160 300 1,900
36,200 18,100 18,100 4,566 140 210 560 2,200 180 2,560 300 2,300
38,200 19,100 19,100 5,091 140 210 560 2,200 180 2,560 300 2,300
40,500 20,250 20,250 5,591 140 210 560 2,200 180 2,560 300 2,300
43,600 21,800 21,800 5,091 140 210 560 2,400 180 2,760 300 2,500
46,100 23,050 23,050 5,591 140 210 560 2,400 180 2,760 300 2,500
NE-11
NE-12
NE-13
NE-14
NE-21
NE-22
NE-23
NE-24
NE-31
NE-32
NE-41
NE-42
NE-51
NE-52
NE-53
NE-61
NE-62
NE-63
NE-71
NE-72
NE-73
NE-81
NE-82
Oper.
AA BB A B C D E F G J K
150
A
G
E F
D
C
AA
BB
J
K
150
A
B
B
D
C
E
F
G
J
K
AA
BB
MODE
SETTING
STOP RUN
CHILLER
BUZZER STOP
STOP LOCAL
REMOTE
OPERATION
ALARM
REF PUMP
#1 ABS PUMP
#2 ABS PUMP
PURGE PUMP
H Generator temp 149.9°C
70100
7070
1200
700300
Remote control ø27
Steam shutoff valve ø21
Power supply
NE-11 thru NE-53 : ø33
NE-61 thru NE-82 : ø41
Steam control valve
NE-11 thru NE-53 : ø21
NE-61 thru NE-82 : ø27
Figure 44. NE-11 Thru NE-42
Figure 46. Control panel
NOTES :
1. The base of machine has ø50 hole for anchor bolt.
2. Anchor bolt should be fixed by shown detail drawing.
Washer should be welded with base.(Refer to Figure 21 page32)
3. There should be a drain ditch around the foundation.
4. The floor surface should be made as water proof for ease of
maintenance work.
5. Surface of foundation should be made flat.
6. Anchor bolts and nuts are supplied by customer.
Table 11. Indication lamp