TF-Series Linear Layout Overview
Burner
Reflector
Tube
Tube/Reflector
Hanger
Coupling
Assembly
LEGEND
a = 14" (36 cm)
reflector width (not shown)
b = 2" (5 cm)
end cap to burner
c = 2" (5 cm)
end cap to hanger
d = 7'6" (229 cm)
distance first hanger
e = 10' (305 cm)
distance between hangers
f = 9.5" (24 cm)
burner height
g = 23.5" (60 cm)
burner length
f
c
b
de
e
30' (9m) Tube Length (each side)
g
TF-160
TF-200
f
c
b
de
e e
40' (12m) Tube Length (each side)
TF-200
TF-250
g
f
TF-120
TF-160
g
c
b
de
20' (6m) Tube Length (each side)
c
b
de
e e e
TF-250
TF-300
TF-350
50' (15m) Tube Length (each side)
f
g
Linear layouts showing one side. Use same measurements for the other side.