Regency P33R-NG2 Indoor Fireplace User Manual


 
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace
6
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location, page 6
b) Clearances to Combustibles, page 6
c) Mantle Clearances, page 7
d) Framing & Finishing Requirements,
page 8
e) Venting Requirements, pages 10 to 15.
2) Assemble Top Facing Support and Side
Nailing Strips, page 8. (NOTE: must be done
before installing unit into fireplace.)
3) Install vent, pages 10 to 19.
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram. Page 20.
Convert to Propane if desired, page 21.
5) Install brick panels (optional), page 22.
6) Install logs and embers and rockwool where
indicated on page 22.
7) Install Flush Door Front (Standard) and
optional Flush Gold Trim, page 23.
8) Install optional Double Screen Door, page
24.
9) Install Optional Bay Front and optional Bay
Gold Trim, page 24.
10)Install Louvers (Flush or Bay), pages 24
and 25.
11)Install optional Wall Switch, Remote Control,
or Wall Thermostat, page 25.
11)Install Optional Fan, page 27.
13)Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) after
burning appliance for 15 minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15-20 min. to
stabilize.
CAUTION: Any alteration to the product
that causes sooting or carboning that
results in damage is not the responsibil-
ity of the manufacturer.
Diagram 1
INSTALLATION
LOCATING YOUR
GAS STOVE
1) When selecting a location for your stove,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or
raised up on a platform to enhance its visual
impact. If the appliance is going to be in-
stalled on carpeting, combustible linoleum
tile or other combustible material other than
wood flooring, the appliance must be in-
stalled on a metal or wood panel extending
the full width and depth of the appliance.
4) The P33R-2 Direct Vent Gas Fireplace can
be installed in a recessed position or framed
out into the room as in A, B, C, D. See Dia.
1.
UNIT DIMENSIONS
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P33R-2 Direct Vent Gas Fireplace is
approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualified inspector, dealer, or installer re-
view your plans before installation.
Note: For vent terminations see page 10.
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
DUCT SYSTEM
OPTION
KIT #946-556
The HeatWave Air Duct Kit increases the
effectiveness of your fireplace by dispersing
warm air from the fireplace to remote locations
in the same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.