OPERATING INSTRUCTIONS
COPY OF THE LIGHTING PLATE INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if not, follow
the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261)
4)Push in control knob all the way and
hold in. Continually push and release
the black button on spark igniter until
pilot lights. Continue to hold the
control knob in for about 1/2 minute
after the pilot is lit. Release knob and
it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 1) to 4).
If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier. If the pilot will
not stay lit after several tries, turn the gas
control knob to “OFF” and call your
service technician or gas supplier.
STOP! Read the safety information
above on this label.
1) Push in gas control knob slightly and
turn clockwise to “OFF”. Knob
cannot be turned from “PILOT” to “OFF”
unless knob is pushed in slightly. Do
not force.
2) Wait five (5) minutes to clear out any
gas. If you then smell gas STOP! follow
“B” in the safety information above on
this label. If you don’t smell gas, go to
the next step.
3)Turn knob on gas control counter-
clockwise to“PILOT”.
1) Push in the gas control knob slightly and
turn clockwise to “OFF”. Do not force.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due
to high surface temperatures keep children, clothing and furniture, gasoline
and other liquids having fammable vapors away. Keep burner and control
compartment clean. See installation and operating instructions
accompanying appliance.
LIGHTING INSTRUCTIONS
5)Turn gas control knob
counterclock-wise
to “ON”.
6)Use rocker switch to op-
erate main burner.
A)This appliance has a pilot which
must be lighted by hand. When
lighting the pilot, follow these
instructions exactly.
B)BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do
not use any phone in your building
- Immediately call your gas supplier
from a neighbours phone. Follow the
gas supplier’s instructions.
- If you cannot reach your gas supplier,
call the fire department.
C)Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
D) Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
This appliance needs fresh air for safe
operation and must be installed so there are
provisions for adequate combustion and
ventilation air.
DO NOT REMOVE THIS INSTRUCTION PLATE
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss
of life. Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to the owner’s information
manual provided with this appliance. For assistance or additional
information consult a qualified installer, service agency or gas supplier.
OFF
ELEMENT
THERMO-
ELECTRIQUE
VEILLEUSE
PILOT BURNER
THERMOPILE
908-017a
2)Turn off all electric power to the
appliance if service is to be performed.