Regency L676E-LP Indoor Fireplace User Manual


 
Regency
®
L676E Direct Vent Gas Fireplace 35
OPERATION
OPERATING INSTRUCTIONS
COPY OF LIGHTING PLATE INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
A) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s
instructions.
- If you cannot reach your gas supplier, call the fi re department.
B) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
C) This appliance needs fresh air for safe operation and must be installed so there are provisions for
adequate combustion and ventilation air.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due
to high surface temperatures keep children, clothing and furniture, gasoline and
other liquids having fl ammable vapors away. Keep burner and control compartment
clean. See installation and operating instructions accompanying appliance.
DO NOT REMOVE THIS INSTRUCTION PLATE
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life. Improper
installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Refer to the owner’s information manual provided with
this appliance. For assistance or additional information consult a qualified
installer, service agency or gas supplier.
918-628
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
Natural Gas and Propane Installation Codes, CSA B149.1.
STOP! Read the safety information above on this label.
1) Press the ON/OFF button once on the Remote Control.
2) If service is to be performed, you must disconnect both sources of power
to the unit; main power and the battery.
1) Plug the power cord into a power outlet.
2) Press and release the ON/OFF button once on the Remote Control.
3) After approximately 3 seconds the spark ignition system will spark for 30
seconds to light the main burner.
4) If the main burner does not light within 90 seconds, you must reset the
unit. See instruction manual for details.